EXPERIMENTAL-STUDY OF THERMAL PERFORMANCE OF AUTOMATED VENETIAN BLIND WINDOW SYSTEMS

被引:7
|
作者
BILGEN, E
机构
[1] Ecole Polytechnique, University of Montreal, Montreal, Que. H3C 3A7
关键词
D O I
10.1016/0038-092X(94)90076-E
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article presents an operational and thermal performance study on automated venetian blind window systems. They are systems with pivoted louvers installed horizontally, sealed hermetically between two glass panes and controlled automatically following the thermal needs. The experimental studies were carried out in two identical test cells (2.43 m high, 1.48 m wide, and 1.92 m deep) used as variable temperature calorimeters. One was equipped with an automated window system and the other double glass window without louvers. Various parameters were measured and recorded: louver angle, inside and outside air temperatures, cloud cover. The operational and thermal performances of the automated louver system have been demonstrated and compared with that of the ordinary system.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 50 条
  • [1] EXPERIMENTAL-STUDY OF FULL-SIZE AUTOMATED VENETIAN BLIND WINDOWS
    RHEAULT, S
    BILGEN, E
    SOLAR ENERGY, 1990, 44 (03) : 157 - 160
  • [2] Shortwave thermal performance for a glass window with a curved venetian blind
    Chaiyapinunt, Somsak
    Khamporn, Nopparat
    SOLAR ENERGY, 2013, 91 : 174 - 185
  • [3] Comparative energy and economic performance analysis of an electrochromic window and automated external venetian blind
    Aste, Niccolo
    Compostella, Junia
    Mazzon, Manlio
    1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 : 404 - 413
  • [4] Experimental and numerical study of heat transfer from a window with an internal Venetian blind
    Nishikawa, Sachiko
    Gomi, Isamu
    Katsumata, Shun
    Kamata, Hiroya
    Nagata, Akihiro
    Kinoshita, Taito
    Sakuma, Eiji
    ENERGY AND BUILDINGS, 2020, 223
  • [5] Experimental study of natural convection in a window with a between-panes venetian blind
    Naylor, D.
    Lai, B. Y.
    EXPERIMENTAL HEAT TRANSFER, 2007, 20 (01) : 1 - 17
  • [6] Energy performance assessment of a window with a horizontal Venetian blind
    Shahid, Hidayat
    Naylor, David
    Energy Build., 8 (836-843):
  • [7] Energy performance assessment of a window with a horizontal Venetian blind
    Shahid, H
    Naylor, D
    ENERGY AND BUILDINGS, 2005, 37 (08) : 836 - 843
  • [8] Thermal resistance of a window with an enclosed venetian blind: A simplified model
    Wright, John L.
    Collins, Michael R.
    Huang, Ned Y. T.
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 471 - +
  • [9] HEAT-TRANSFER ANALYSIS IN AN AUTOMATED VENETIAN BLIND WINDOW SYSTEM
    RHEAULT, S
    BILGEN, E
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (01): : 89 - 95
  • [10] Effect of installing a venetian blind to a glass window on human thermal comfort
    Khamporn, Nopparat
    Chaiyapinunt, Somsak
    BUILDING AND ENVIRONMENT, 2014, 82 : 713 - 725