A static beam delivery device for fast scanning proton arc-therapy

被引:12
|
作者
Nesteruk, K. P. [1 ]
Bolsi, A. [1 ]
Lomax, A. J. [1 ,2 ]
Meer, D. [1 ]
van de Water, S. [1 ]
Schippers, J. M. [1 ]
机构
[1] Paul Scherrer Inst, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 05期
关键词
proton-arc therapy; static beam delivery device; fast dose delivery; IMPLEMENTATION;
D O I
10.1088/1361-6560/abe02b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called 'arcs'). This technique can potentially yield a better dose conformity around the tumor and a very low dose in the surrounding healthy tissue. Currently, proton-arc therapy is performed by rotating a proton gantry around the patient, adapting the normally used dose-delivery method to the arc-specific motion of the gantry. Here we present first results from a feasibility study of the conceptual design of a new static fast beam delivery device/system for proton-arc therapy, which could be used instead of a gantry. In this novel concept, the incident angle of proton beams can be set rapidly by only changing field strengths of small magnets. This device eliminates the motion of the heavy gantry and related hardware. Therefore, a reduction of the total treatment time is expected. In the feasibility study presented here, we concentrate on the concept of the beam transport. Based on several simple, but realistic assumptions and approximations, proton tracking calculations were performed in a 3D magnetic field map, to calculate the beam transport in this device and to investigate and address several beam-optics challenges. We propose and simulate corresponding solutions and discuss their outcomes. To enable the implementation of some usually applied techniques in proton therapy, such as pencil beam scanning, energy modulation and beam shaping, we present and discuss our proposals. Here we present the concept of a new idea to perform fast proton arc-scanning and we report on first results of a feasibility study. Based on these results, we propose several options and next steps in the design.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Motion Management for Pencil Beam Scanning Proton Therapy
    Lin, Liyong
    MEDICAL PHYSICS, 2016, 43 (06) : 3821 - 3821
  • [32] 3-DIMENSIONAL BEAM SCANNING FOR PROTON THERAPY
    KANAI, T
    KAWACHI, K
    MATSUZAWA, H
    INADA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 491 - 496
  • [33] Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy
    Sengbusch, E.
    Perez-Andujar, A.
    DeLuca, P. M., Jr.
    Mackie, T. R.
    MEDICAL PHYSICS, 2009, 36 (02) : 364 - 372
  • [34] Explore the Potential Clinical and Dosimetric Improvements for Brain Cancer Proton Beam Treatment Based on the New Delivery and Planning Technique Developments - Collimator Based Intensity Modulated Proton Therapy and Spot-Scanning Proton Arc Therapy
    Ding, X.
    Li, X.
    Zhou, J.
    Stevens, C. W.
    Yan, D.
    Chinnaiyan, P.
    Kabolizadeh, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E490 - E490
  • [35] Commissioning and Dosimetric Assessment of a Range Shifter Helmet as An Energy Absorber Device for Scanning Beam Proton Therapy
    Allred, B.
    Mundy, D.
    Furutani, K.
    Beltran, C.
    Saunders, A.
    Patel, S.
    Rwigema, J.
    Shen, J.
    Robertson, D.
    Lara, P.
    McGee, L.
    Bues, M.
    Anand, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E598 - E598
  • [36] Fast and accurate position verification algorithms for dose delivery system in proton therapy scanning nozzle system
    Lin, Yinjie
    Tan, Ping
    Guo, Huidong
    Zhang, Lige
    Lei, Hao
    Yu, Yecheng
    Li, Xingyu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 986
  • [37] Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer
    Apinorasethkul, Ontida
    Kirk, Maura
    Teo, Kevin
    Swisher-McClure, Samuel
    Lukens, John N.
    Lin, Alexander
    MEDICAL DOSIMETRY, 2017, 42 (01) : 7 - 11
  • [38] Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence
    Li, H.
    Zhang, X.
    Li, Y.
    Zhu, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 551 - 552
  • [39] Impact of interfractional motion on hypofractionated pencil beam scanning proton therapy and VMAT delivery for prostate cancer
    Moteabbed, Maryam
    Trofimov, Alexei
    Khan, Fazal H.
    Wang, Yi
    Sharp, Gregory C.
    Zietman, Anthony L.
    Efstathiou, Jason A.
    Lu, Hsiao-Ming
    MEDICAL PHYSICS, 2018, 45 (09) : 4011 - 4019
  • [40] Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning
    Sanchez-Parcerisa, Daniel
    Kirk, Maura
    Fager, Marcus
    Burgdorf, Brendan
    Stowe, Malorie
    Solberg, Tim
    Carabe, Alejandro
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21): : N565 - N574