A static beam delivery device for fast scanning proton arc-therapy

被引:12
|
作者
Nesteruk, K. P. [1 ]
Bolsi, A. [1 ]
Lomax, A. J. [1 ,2 ]
Meer, D. [1 ]
van de Water, S. [1 ]
Schippers, J. M. [1 ]
机构
[1] Paul Scherrer Inst, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 05期
关键词
proton-arc therapy; static beam delivery device; fast dose delivery; IMPLEMENTATION;
D O I
10.1088/1361-6560/abe02b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called 'arcs'). This technique can potentially yield a better dose conformity around the tumor and a very low dose in the surrounding healthy tissue. Currently, proton-arc therapy is performed by rotating a proton gantry around the patient, adapting the normally used dose-delivery method to the arc-specific motion of the gantry. Here we present first results from a feasibility study of the conceptual design of a new static fast beam delivery device/system for proton-arc therapy, which could be used instead of a gantry. In this novel concept, the incident angle of proton beams can be set rapidly by only changing field strengths of small magnets. This device eliminates the motion of the heavy gantry and related hardware. Therefore, a reduction of the total treatment time is expected. In the feasibility study presented here, we concentrate on the concept of the beam transport. Based on several simple, but realistic assumptions and approximations, proton tracking calculations were performed in a 3D magnetic field map, to calculate the beam transport in this device and to investigate and address several beam-optics challenges. We propose and simulate corresponding solutions and discuss their outcomes. To enable the implementation of some usually applied techniques in proton therapy, such as pencil beam scanning, energy modulation and beam shaping, we present and discuss our proposals. Here we present the concept of a new idea to perform fast proton arc-scanning and we report on first results of a feasibility study. Based on these results, we propose several options and next steps in the design.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Ultra-fast scintillator-based dosimeter for pencil beam scanning proton FLASH therapy
    Kanouta, E.
    Johansen, J.
    Kertzscher, G.
    Sitarz, M.
    Sorensen, B.
    Poulsen, P.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S388 - S390
  • [42] Comparison of dosimetries of carbon-ion pencil beam scanning, proton pencil beam scanning and volumetric modulated arc therapy for locally recurrent rectal cancer
    Mori, Shinichiro
    Bhattacharyya, Tapesh
    Furuichi, Wataru
    Tohyama, Naoki
    Nomoto, Akihiro
    Shinoto, Makoto
    Takiyama, Hirotoshi
    Yamada, Shigeru
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 162 - 170
  • [43] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Liu, C.
    Ho, M.
    Park, J.
    Hsi, W.
    Liang, X.
    Li, Z.
    Song, Y.
    Feng, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [44] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Liu, Chunbo
    Ho, Meng Wei
    Park, Jiyeon
    Hsi, Wen Chien
    Liang, Xiaoying
    Li, Zuofeng
    Song, Yuntao
    Feng, Hansheng
    Zhang, Yawei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [45] Spot scanning arc therapy: From concept to first delivery
    Ding, X.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S91 - S92
  • [46] The Effects of Pencil Beam Scanning Proton Beam Therapy on a HeartMate 3 Left Ventricular Assist Device: Implications for Patient Safety
    Sindhu, Kunal K.
    Shi, Chengyu
    Moss, Noah
    Lin, Haibo
    Zhang, Jingqiao
    Hu, Lei
    Sharma, Sonam
    Bakst, Richard L.
    Chhabra, Arpit
    Simone, Charles B.
    Salgado, Lucas Resende
    ASAIO JOURNAL, 2022, 68 (09) : E145 - E147
  • [47] Development of a standalone delivery sequence model for proton arc therapy
    Liu, Gang
    Zhao, Lewei
    Liu, Peilin
    Yan, Di
    Deraniyagala, Rohan
    Stevens, Craig
    Li, Xiaoqiang
    Ding, Xuanfeng
    MEDICAL PHYSICS, 2024, 51 (04) : 3067 - 3075
  • [48] Energy Thresholds in 180 Degree Arc Delivery Proton Therapy
    Sengbusch, E.
    Mackie, T.
    Perez-Andujar, A.
    DeLuca, P.
    MEDICAL PHYSICS, 2008, 35 (06) : 2846 - +
  • [49] Commissioning of a Facility-Specific Beam Data Library for a Fast Monte Carlo Code for Pencil Beam Scanning Proton Therapy
    Hong, L.
    Souris, K.
    Cohilis, M.
    Rossomme, S.
    Liu, H.
    Li, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E587 - E587
  • [50] Quantifying Lateral Penumbra with a Prototype Aperture for Pencil Beam Scanning Proton Beam Delivery
    Ewart, S.
    Zimmerman, S.
    Lee, E.
    Speth, J.
    Mascia, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E837 - E837