Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning

被引:25
|
作者
Sanchez-Parcerisa, Daniel [1 ,2 ]
Kirk, Maura [1 ]
Fager, Marcus [1 ]
Burgdorf, Brendan [1 ]
Stowe, Malorie [1 ]
Solberg, Tim [1 ]
Carabe, Alejandro [1 ]
机构
[1] Hosp Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Bvd, Philadelphia, PA 19104 USA
[2] Univ Complutense Madrid, Dept Fis Atom Mol & Nucl, Fac Ciencias Fis, Ave Complutense S-N, E-28040 Madrid, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 21期
关键词
protontherapy; pencil beam scanning; arc therapy; RELATIVE BIOLOGICAL EFFECTIVENESS; ROBUST OPTIMIZATION; RADIOTHERAPY; PROSTATE; BRAIN; MODEL;
D O I
10.1088/0031-9155/61/21/N565
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of rotational proton therapy plans based on a pencil-beam-scanning (PBS) system has been limited, among several other factors, by the energy-switching time between layers, a system-dependent parameter that ranges between a fraction of a second and several seconds. We are investigating mono-and bi-energetic rotational proton modulated arc therapy (PMAT) solutions that would not be affected by long energy switching times. In this context, a systematic selection of the optimal proton energy for each arc is vital. We present a treatment planning comparison of four different range selection methods, analyzing the dosimetric outcomes of the resulting treatment plans created with the ranges obtained. Given the patient geometry and arc definition (gantry and couch trajectories, snout elevation) our in-house treatment planning system (TPS) FoCa was used to find the maximum, medial and minimum water-equivalent thicknesses (WETs) of the target viewed from all possible field orientations. Optimal ranges were subsequently determined using four methods: (1) by dividing the max/ min WET interval into equal steps, (2) by taking the average target midpoints from each field, (3) by taking the average WET of all voxels from all field orientations, and (4) by minimizing the fraction of the target which cannot be reached from any of the available angles. After the range (for mono-energetic plans) or ranges (for bi-energetic plans) were selected, the commercial clinical TPS in use in our institution (Varian Eclipse T) was used to produce the PMAT plans using multifield optimization. Linear energy transfer (LET) distributions of all plans were also calculated using FoCa and compared among the different methods. Mono- and bi-energetic PMAT plans, composed of a single 180 degrees arc, were created for two patient geometries: a C-shaped target located in the mediastinal area of a thoracic tissue-equivalent phantom and a small brain tumor located directly above the brainstem. All plans were optimized using the same procedure to (1) achieve target coverage, (2) reduce dose to OAR and (3) limit dose hot spots in the target. Final outcomes were compared in terms of the resulting dose and LET distributions. Data shows little significant differences among the four studied methods, with superior results obtained with mono-energetic plans. A streamlined systematic method has been implemented in an in-house TPS to find the optimal range to maximize target coverage with rotational mono-or bi-energetic PBS rotational plans by minimizing the fraction of the target that cannot be reached by any direction.
引用
收藏
页码:N565 / N574
页数:10
相关论文
共 50 条
  • [1] Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning
    Beltran, C.
    Kamal, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3510 - 3510
  • [2] Comparison of dosimetries of carbon-ion pencil beam scanning, proton pencil beam scanning and volumetric modulated arc therapy for locally recurrent rectal cancer
    Mori, Shinichiro
    Bhattacharyya, Tapesh
    Furuichi, Wataru
    Tohyama, Naoki
    Nomoto, Akihiro
    Shinoto, Makoto
    Takiyama, Hirotoshi
    Yamada, Shigeru
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 162 - 170
  • [3] Pencil Beam Dose Algorithm for Intensity Modulated Proton Therapy with Scanning Proton Beams
    Wang, H.
    Zheng, H.
    Cao, R.
    Jia, J.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Introduction to Pencil Beam Scanning Proton Therapy
    Zhu, M.
    Mossahebi, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E275 - E276
  • [5] Dosimetric comparison of volumetric modulated arc therapy and proton pencil beam scanning technique under deep inspiration breath hold
    Chen, J.
    Shen, Y. L.
    Tsai, P. F.
    Lee, S. H.
    Wang, P. I.
    Chang, F.
    Liu, Y. C.
    Chang, J. T. C.
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : S126 - S126
  • [6] Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy
    Xie, Yunhe
    Bentefour, El Hassane
    Janssens, Guillaume
    Smeets, Julien
    Vander Stappen, Francois
    Hotoiu, Lucian
    Yin, Lingshu
    Dolney, Derek
    Avery, Stephen
    O'Grady, Fionnbarr
    Prieels, Damien
    McDonough, James
    Solberg, Timothy D.
    Lustig, Robert A.
    Lin, Alexander
    Teo, Boon-Keng K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01): : 210 - 218
  • [7] Proton Modulated Arc Therapy Using Scanned Pencil Beams
    Carabe-Fernandez, A.
    Kirk, M.
    Sanchez-Parcerisa, D.
    Fager, M.
    Burgdorf, B.
    Stowe, M.
    Solberg, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3483 - 3483
  • [8] Gantry-based pencil beam scanning proton therapy for uveal melanoma: IMPT versus proton arc therapy
    Qi, Hang
    Hu, Lei
    Huang, Sheng
    Lee, Yen-Po
    Yu, Francis
    Chen, Qing
    Yang, Yunjie
    Kang, Minglei
    Zhai, Huifang
    Vermeulen, Milo
    Shim, Andy
    Park, Peter
    Ding, Xuanfeng
    Zhou, Jun
    Abramson, David H.
    Francis, Jasmine H.
    Simone, Charles B.
    Barker, Christopher A.
    Lin, Haibo
    RADIATION ONCOLOGY, 2025, 20 (01)
  • [9] Motion Management for Pencil Beam Scanning Proton Therapy
    Lin, Liyong
    MEDICAL PHYSICS, 2016, 43 (06) : 3821 - 3821
  • [10] Pencil Beam Scanning:: a dynamical approach to proton therapy
    Sepulchre, R
    Gérard, M
    Marchand, B
    Prieels, D
    Bauvir, B
    IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 370 - 375