MEASUREMENT AND COMPARISON OF MULTI-ELECTRODE PLACEMENT FOR BIOELECTRICAL IMPEDANCE ANALYSIS

被引:0
|
作者
West, Daniel [1 ]
Choi, JungHun [1 ]
机构
[1] Georgia Southern Univ, Dept Mech Engn, Statesboro, GA 30459 USA
关键词
Bioelectrical Impedance Spectroscopy; Cole-Cole Plot; Body Composition; Electrical Impedance Myography;
D O I
10.1115/DMD2019-3265
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The purpose of this examination was to determine a) how bioimpedance scanning generates data about the human body and b) compare the Bodystat Multiscan 5000 and the Skulpt Chisel. The Bodystat Multiscan 5000 is bioelectrical impedance spectroscopy (BIS) device that performs a scan of 50 measurements, from 5 kHz to 1000 kHz. This scan generates a 2d Cole analysis plot that compares the resistance and reactance of the scanned muscle group. Higher frequencies measure the amount of intracellular fluid (ICF), and lower frequencies measure the amount of extracellular fluid (ECF). Lower values for the resistance and reactance relate to a greater level of fitness for the scanned area. The Skulpt Chisel is an electrical impedance myography (EIM) that performs a single 50 kHz measurement. This scan determines the muscle quality and percent body fat of the scanned muscle group. The test subject was scanned with each device. Each plane was scanned three times with the Bodystat Multiscan 5000, and scanned five times with the Skulpt Chisel. The data was recorded to Excel and analyzed using MATLAB. The Bodystat Multiscan measurements for the surfaces were examined at a frequency of 50 kHz to be comparable to the Skulpt Chisel data. The surfaces are recorded in descending order of magnitude for resistance: medial, 22.14 Omega; anterior, 20.31 Omega; posterior, 17.89 Omega, lateral, 12.6 Omega. The Cole Analysis for the right thigh at 45-degree intervals are recorded in descending order of magnitude for resistance: medial/posterior, 23.89 Omega; posterior/lateral, 23.06 Omega; anterior/medial, 21.09 Omega, lateral/anterior, 16.13 Omega. The Skulpt Chisel surfaces are recorded in an increasing order of magnitude, the first value being muscle quality and the second value being percent body fat: lateral, 81.12, 13.1%; posterior, 62.22, 16.46%; anterior, 50.88, 19.24%; medial, 42.16, 23.16%. The data display an inverse relationship between resistance/reactance and muscle quality, and a direct relationship between resistance/reactance and percent body fat. The larger the magnitude of the resistance/reactance recorded for a muscle group, the lower the level of muscle quality will be. This leads to a larger percent body fat value.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Novel method for electrode-tissue contact measurement with multi-electrode catheters
    van Es, Ren
    Hauck, John
    van Driel, Vincent J. H. M.
    Neven, Kars
    van Wessel, Harry
    A Doevendans, Pieter
    Wittkampf, Fred H. M.
    EUROPACE, 2018, 20 (01): : 149 - 156
  • [22] Optimization of the multi-electrode electrostatic sensor for velocity distribution measurement
    Wang, Chao
    Zhang, Wenbiao
    Wu, Weiping
    8TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS, 2014, 1592 : 43 - 49
  • [23] Real-Time Monitoring Using Multiplexed Multi-Electrode Bioelectrical Impedance Spectroscopy for the Stratification of Vascularized Composite Allografts: A Perspective on Predictive Analytics
    Aggas, John R.
    Abasi, Sara
    Ton, Carolyn
    Salehi, Sara
    Liu, Renee
    Brandacher, Gerald
    Grayson, Warren L.
    Guiseppi-Elie, Anthony
    BIOENGINEERING-BASEL, 2023, 10 (04):
  • [24] Multi-electrode stretching catheter for creation of linear radiofrequency lesions in the atrium: Comparison with standard multi-electrode design and dragging approach
    Natale, A
    Beheiry, S
    Barold, H
    Tomassoni, G
    Lein, L
    Dixon-Tullaoch, E
    Jensen, D
    Geiser, J
    Wolf, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 255A - 255A
  • [25] Comparison of Bioelectrical Impedance Analysis and Air Displacement Plethysmography
    Coufalova, Klara
    Komarc, Martin
    Cochrane, Darryl James
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2019, 37 (03): : 985 - 990
  • [26] Proximal electrode placement improves the estimation of body composition in obese and lean elderly during segmental bioelectrical impedance analysis
    Yosuke Yamada
    Yoshihisa Masuo
    Keiichi Yokoyama
    Yukako Hashii
    Soichi Ando
    Yasuko Okayama
    Taketoshi Morimoto
    Misaka Kimura
    Shingo Oda
    European Journal of Applied Physiology, 2009, 107 : 135 - 144
  • [27] Proximal electrode placement improves the estimation of body composition in obese and lean elderly during segmental bioelectrical impedance analysis
    Yamada, Yosuke
    Masuo, Yoshihisa
    Yokoyama, Keiichi
    Hashii, Yukako
    Ando, Soichi
    Okayama, Yasuko
    Morimoto, Taketoshi
    Kimura, Misaka
    Oda, Shingo
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (02) : 135 - 144
  • [28] COMPARISON ANALYSIS ERRORS OF CORRELATION METHODS FOR FAST MEASUREMENT ELECTRODE IMPEDANCE
    NOVITSCIY, SP
    SHURAEVA, LI
    JOLCIN, VV
    IZVESTIYA SIBIRSKOGO OTDELENIYA AKADEMII NAUK SSSR SERIYA KHIMICHESKIKH NAUK, 1990, (05): : 38 - 44
  • [29] The analysis of electrode-recording-horizon in multi-electrode array(MEA)
    Lin, Yunsheng
    Chen, Chuanping
    Chen, Lin
    Zeng, Shaoqun
    Luo, Qingming
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7345 - 7348
  • [30] EFFECTS OF SMALL ERRORS IN ELECTRODE PLACEMENT ON BODY-COMPOSITION ASSESSMENT BY BIOELECTRICAL-IMPEDANCE
    DUNBAR, CC
    MELAHRINIDES, E
    MICHIELLI, DW
    KALINSKI, MI
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1994, 65 (03) : 291 - 294