Optimization of the multi-electrode electrostatic sensor for velocity distribution measurement

被引:0
|
作者
Wang, Chao [1 ]
Zhang, Wenbiao [1 ]
Wu, Weiping [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin Key Lab Proc Measurement & Control, Tianjin 300072, Peoples R China
关键词
velocity distribution; sensor optimization; multi-electrode electrostatic sensor; effective correlation calculation;
D O I
10.1063/1.4872084
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Measuring the velocity distribution of dilute gas-solid two-phase flow is necessary for industrial process monitor and control. However, in order to get correct measurement of the velocity distribution, the effective correlation calculation by non-corresponding side electrode couples of the electrostatic sensor was needed. By introducing the principle of electrostatic correlation based velocity distribution measurement method, the importance of the effective correlation calculation by non-corresponding side electrode couples was emphasized in this paper. In order to ensure effective correlation calculation by non-corresponding side electrode couples was emphasized in this paper. In order to ensure effective correlation calculation by non-corresponding side electrode couples, effective correlation analysis of multi-electrode electrostatic sensor was carried out and effective correlation analysis method was proposed. According to this method, the structure of multi-electrode electrostatic sensor was optimized. Finally, experimental results show that correlation calculation of non-corresponding side electrode couples could be done effectively by the optimized multi-electrode electrostatic sensor. This result lays a foundation for further research on velocity distribution measurement.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [1] A Multi-electrode Biomimetic Electrolocation Sensor
    Mayekar, K.
    Damalla, D.
    Gottwald, M.
    Bousack, H.
    von der Emde, G.
    BIOINSPIRATION, BIOMIMETICS, AND BIOREPLICATION 2012, 2012, 8339
  • [2] Measurement of velocity profiles in multiphase flow using a multi-electrode electromagnetic flow meter
    Leeungculsatien, T.
    Lucas, G. P.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 31 : 86 - 95
  • [3] Measurement of grounding resistance by multi-electrode arrangement
    Zhang, Dandan
    Yin, Xiaogen
    Chen, Junwu
    Li, Zaoxiang
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (05):
  • [4] Analytic determination of electrostatic potentials for simple multi-electrode lenses
    Reuben, Andreas J.
    Optik (Jena), 1998, 109 (02): : 49 - 60
  • [5] Research on multi-electrode capacitance rod position measurement sensor for NHR-200
    Li, Yanlin
    Qin, Benke
    Bo, Hanliang
    ANNALS OF NUCLEAR ENERGY, 2022, 166
  • [6] The analytic determination of electrostatic potentials for simple multi-electrode lenses
    Reuben, AJ
    OPTIK, 1998, 109 (02): : 49 - 60
  • [7] Parametric Optimization of Multi-Electrode Plasma Actuator with Serrated Electrode
    Matsuno, T.
    Fukuda, A.
    Kawazoe, H.
    Nakai, K.
    Nishida, H.
    14TH INTERNATIONAL CONFERENCE ON FLUID CONTROL, MEASUREMENTS AND VISUALIZATION (FLUCOME 2017), 2017, 249
  • [8] Optimization of Uniplanar Multi-electrode Capacitive Sensor for Damage Detection of Aircraft Composite Material
    Dong Ensheng
    Yu Xiangbin
    Chao He
    PROCEEDINGS OF 2013 IEEE 11TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2013, : 244 - 248
  • [9] Research on Static Characteristics of Multi-electrode Capacitance Rod Position Measurement Sensor Based on Principle of Rotating Electrode
    Li Y.
    Qin B.
    Bo H.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (04): : 664 - 671
  • [10] Simulation and experiment for a uniplanar capacitance sensor with multi-electrode
    State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China
    Jixie Gongcheng Xuebao, 2006, 2 (6-11):