MEASUREMENT AND COMPARISON OF MULTI-ELECTRODE PLACEMENT FOR BIOELECTRICAL IMPEDANCE ANALYSIS

被引:0
|
作者
West, Daniel [1 ]
Choi, JungHun [1 ]
机构
[1] Georgia Southern Univ, Dept Mech Engn, Statesboro, GA 30459 USA
关键词
Bioelectrical Impedance Spectroscopy; Cole-Cole Plot; Body Composition; Electrical Impedance Myography;
D O I
10.1115/DMD2019-3265
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The purpose of this examination was to determine a) how bioimpedance scanning generates data about the human body and b) compare the Bodystat Multiscan 5000 and the Skulpt Chisel. The Bodystat Multiscan 5000 is bioelectrical impedance spectroscopy (BIS) device that performs a scan of 50 measurements, from 5 kHz to 1000 kHz. This scan generates a 2d Cole analysis plot that compares the resistance and reactance of the scanned muscle group. Higher frequencies measure the amount of intracellular fluid (ICF), and lower frequencies measure the amount of extracellular fluid (ECF). Lower values for the resistance and reactance relate to a greater level of fitness for the scanned area. The Skulpt Chisel is an electrical impedance myography (EIM) that performs a single 50 kHz measurement. This scan determines the muscle quality and percent body fat of the scanned muscle group. The test subject was scanned with each device. Each plane was scanned three times with the Bodystat Multiscan 5000, and scanned five times with the Skulpt Chisel. The data was recorded to Excel and analyzed using MATLAB. The Bodystat Multiscan measurements for the surfaces were examined at a frequency of 50 kHz to be comparable to the Skulpt Chisel data. The surfaces are recorded in descending order of magnitude for resistance: medial, 22.14 Omega; anterior, 20.31 Omega; posterior, 17.89 Omega, lateral, 12.6 Omega. The Cole Analysis for the right thigh at 45-degree intervals are recorded in descending order of magnitude for resistance: medial/posterior, 23.89 Omega; posterior/lateral, 23.06 Omega; anterior/medial, 21.09 Omega, lateral/anterior, 16.13 Omega. The Skulpt Chisel surfaces are recorded in an increasing order of magnitude, the first value being muscle quality and the second value being percent body fat: lateral, 81.12, 13.1%; posterior, 62.22, 16.46%; anterior, 50.88, 19.24%; medial, 42.16, 23.16%. The data display an inverse relationship between resistance/reactance and muscle quality, and a direct relationship between resistance/reactance and percent body fat. The larger the magnitude of the resistance/reactance recorded for a muscle group, the lower the level of muscle quality will be. This leads to a larger percent body fat value.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Multi-electrode tunable lasers
    Fish, GA
    Larson, MC
    ACTIVE AND PASSIVE OPTICAL COMPONENTS FOR WDM COMMUNICATION, 2001, 4532 : 37 - 40
  • [42] Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector
    Forneris, Jacopo
    Grilj, Veljko
    Jaksic, Milko
    Olivero, Paolo
    Picollo, Federico
    Skukan, Natko
    Verona, Claudio
    Verona-Rinati, Gianluca
    Vittone, Ettore
    EPL, 2013, 104 (02)
  • [43] Design of a Four-Annulus Integrated Disk Electrode for Bioelectrical Impedance Spectroscopy Measurement
    Wang, Kening
    Zhang, Xiongxing
    Wang, Wei
    INTELLIGENCE COMPUTATION AND EVOLUTIONARY COMPUTATION, 2013, 180 : 297 - 303
  • [44] The measurement of body composition by bioelectrical impedance
    Popa, Monica
    Sirbu, Dana
    Curseu, Daniela
    Ionutas, Alina
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 2, PROCEEDINGS, 2006, : 437 - 440
  • [45] Comparison of anthropometry and bioelectrical impedance analysis (BIA) in Ecuadorian children
    Havens, RD
    Heine, J
    Trinidad, S
    Going, S
    Cordero-MacIntyre, Z
    FASEB JOURNAL, 2003, 17 (05): : A1206 - A1206
  • [46] Reliability of multiple frequency bioelectrical impedance analysis: An intermachine comparison
    Ward, LC
    Byrne, NM
    Rutter, K
    Hennoste, L
    Hills, AP
    Cornish, BH
    Thomas, BJ
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 1997, 9 (01) : 63 - 72
  • [47] Use of different segmental multi-frequency bioelectrical impedance devices for analysis of body composition in young adults: comparison with bioelectrical spectroscopy
    Guedes, Dartagnan Pinto
    Calabrese, Jean Carlos
    Pirolli, Paulo Marcelo
    NUTRICION HOSPITALARIA, 2019, 36 (03) : 618 - 625
  • [48] Bioelectrical impedance analysis in dialysis patients: Comparison to NHANES III
    Dumler, F
    FASEB JOURNAL, 2001, 15 (05): : A1000 - A1000
  • [49] Reservoir Computing Model For Multi-Electrode Electrophysiological Data Analysis
    Auslender, Ilya
    Pavesi, Lorenzo
    2023 IEEE CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN BIOINFORMATICS AND COMPUTATIONAL BIOLOGY, CIBCB, 2023, : 151 - 156
  • [50] Optogenetic Modulation and Multi-Electrode Analysis of Cerebellar Networks In Vivo
    Kruse, Wolfgang
    Krause, Martin
    Aarse, Janna
    Mark, Melanie D.
    Manahan-Vaughan, Denise
    Herlitze, Stefan
    PLOS ONE, 2014, 9 (08):