Clinical performance evaluation of the new hematology analyzer Mindray BC-6000

被引:4
|
作者
Shen, Yimin [1 ]
Cao, Jun [1 ]
Zhou, Zhiying [1 ]
Wang, Yong [1 ]
Shen, Yili [1 ]
He, Jun [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Lab Med, Suzhou 215031, Peoples R China
关键词
BC-6000; body fluid; flagging ability; hematology analyzer; methods comparison; performance evaluation; repeatability; reproducibility; BODY-FLUID MODE; UNICEL DXH 800; CEREBROSPINAL-FLUID; VALIDATION; MODULE; COUNT; CELLS;
D O I
10.1111/ijlh.13075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. Methods Methods comparison was performed using 350 blood samples from patients between different measurement procedures; the basic analytical performance was also tested, including the throughput, carryover, precision, and linearity in different modes. The flagging performances for blasts, immature granulocytes, and NRBC were compared with manual microscopy. Results There were minimal carryover (<0.30%) and excellent actual blood linearity for all routinely used parameters concerned by the clinicians (R-2 >= 0.997). Repeatability and reproducibility were satisfactory at all testing levels. The functional sensitivity of leukocytes and platelets in the blood and leukocytes and erythrocytes in body fluid was excellent at the 20% CV level. BC-6000 and XN displayed very high correlations for complete blood count (CBC) parameters and very high consistency for leukocyte differentials and NRBC compared with manual microscopy. BC-6000 showed excellent sensitivity and specificity flagging ability on blasts (82.9% and 82.4%) and NRBC (80.0% and 96.9%). For immature granulocytes, BC-6000 showed excellent sensitivity but common specificity flagging ability (91.7% and 65.6%). Conclusion The clinical performance of BC-6000 is excellent, and the analyzer can provide timely and accurate reporting for most of the small- to large-scale laboratories.
引用
收藏
页码:622 / 634
页数:13
相关论文
共 50 条
  • [31] Performance evaluation of new Abbott Alinity hq hematology analyzer
    Woo, Kwang-Sook
    Jeong, In-Hwa
    An, Gyu-Dae
    Lim, Hyeon-Ho
    Han, Jin-Yeong
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 (05) : 657 - 663
  • [32] Hemoglobin Shelby interfered with the leukocyte differential channel of the Mindray BC-6800Plus hematology analyzer: a case report
    Urrechaga, Eloisa
    Merino, Monica
    Fernandez, Monica
    Aguirrezabal, Jaione
    del Orbe, Rafael
    JOURNAL OF LABORATORY AND PRECISION MEDICINE, 2022, 7
  • [33] Hemoglobin Shelby interfered with the leukocyte differential channel of the Mindray BC-6800Plus hematology analyzer: a case report
    Urrechaga, Eloisa
    Merino, Monica
    Fernandez, Monica
    Aguirrezabal, Jaione
    del Orbe, Rafael
    JOURNAL OF LABORATORY AND PRECISION MEDICINE, 2022, 7
  • [34] Performance evaluation of HbAlc (%) on the cobas® 6000 analyzer
    Whelan, P. V.
    Bryson, A.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A164 - A164
  • [35] Prediction of Ehrlichia canis and Babesia canis in canine blood sample by Mindray BC-5000 Vet hematology analyzer
    Thongsahuan, Sorawat
    Buncherd, Hansuk
    Thanapongpichat, Supinya
    Noosong, Sataporn
    Choobunsong, Siriyaporn
    Srinoun, Kanitta
    THAI JOURNAL OF VETERINARY MEDICINE, 2023, 53 (01): : 139 - 148
  • [36] Performance evaluation the new automated Atellica Hema 580 hematology analyzer
    Schapkaitz, E.
    Baiden, A.
    Raburabu, S.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 (01) : 63 - 71
  • [37] Performance evaluation of the new hematology analyzer Sysmex XN-series
    Seo, J. Y.
    Lee, S. -T.
    Kim, S. -H.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (02) : 155 - 164
  • [38] Evaluation of performance parameters of an automated hematology analyzer
    Pares, Jesica
    Borda, Natalia
    Damian Santiago, Sergio
    Benito, Cristina
    Aranda, Claudio
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2015, 49 (04): : 399 - 407
  • [39] EVALUATION OF THE MINDRAY BC-6800 AND BC-3600 AUTOMATED HEMATOLOGY ANALYZERS FOR SCREENING OF THALASSEMIA IN SOUTHEAST ASIAN POPULATIONS
    Paiboonsukwong, Kittiphong
    Sirankapracha, Pornpan
    Wapeesitthiphan, Nitsara
    Khampan, Pornnapa
    Thamprasert, Wichuda
    Svasti, Saovaros
    Winichagoon, Pranee
    Fucharoen, Suthat
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 : 72 - 72
  • [40] Compare the accuracy and precision of Coulter LH780, Mindray BC-6000 Plus, and Sysmex XN-9000 with the international reference flow cytometric method in platelet counting
    Yi Sun
    Hu, Zuojian
    Huang, Zhili
    Chen, Huaping
    Qin, Shanzi
    Zhong Jianing
    Chen, Siyuan
    Xue Qin
    Yi Ye
    Wang, Chengbin
    PLOS ONE, 2019, 14 (05):