Clinical performance evaluation of the new hematology analyzer Mindray BC-6000

被引:4
|
作者
Shen, Yimin [1 ]
Cao, Jun [1 ]
Zhou, Zhiying [1 ]
Wang, Yong [1 ]
Shen, Yili [1 ]
He, Jun [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Lab Med, Suzhou 215031, Peoples R China
关键词
BC-6000; body fluid; flagging ability; hematology analyzer; methods comparison; performance evaluation; repeatability; reproducibility; BODY-FLUID MODE; UNICEL DXH 800; CEREBROSPINAL-FLUID; VALIDATION; MODULE; COUNT; CELLS;
D O I
10.1111/ijlh.13075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. Methods Methods comparison was performed using 350 blood samples from patients between different measurement procedures; the basic analytical performance was also tested, including the throughput, carryover, precision, and linearity in different modes. The flagging performances for blasts, immature granulocytes, and NRBC were compared with manual microscopy. Results There were minimal carryover (<0.30%) and excellent actual blood linearity for all routinely used parameters concerned by the clinicians (R-2 >= 0.997). Repeatability and reproducibility were satisfactory at all testing levels. The functional sensitivity of leukocytes and platelets in the blood and leukocytes and erythrocytes in body fluid was excellent at the 20% CV level. BC-6000 and XN displayed very high correlations for complete blood count (CBC) parameters and very high consistency for leukocyte differentials and NRBC compared with manual microscopy. BC-6000 showed excellent sensitivity and specificity flagging ability on blasts (82.9% and 82.4%) and NRBC (80.0% and 96.9%). For immature granulocytes, BC-6000 showed excellent sensitivity but common specificity flagging ability (91.7% and 65.6%). Conclusion The clinical performance of BC-6000 is excellent, and the analyzer can provide timely and accurate reporting for most of the small- to large-scale laboratories.
引用
收藏
页码:622 / 634
页数:13
相关论文
共 50 条
  • [21] Performance evaluation of BC-3200 hematology analyzer in a university hospital
    Peng, L.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A134 - A134
  • [22] Performance Evaluation of Mindray SAL 8000: a New Integrated Clinical Chemistry and Immunoassay Analyzer System
    Yang, Jie
    Li, Maocheng
    Zhang, Hanyun
    Zhang, Peng
    Zhao, Lifei
    Zeng, Deyu
    Li, Ling
    Fan, Huihui
    Zeng, Fangyin
    CLINICAL LABORATORY, 2019, 65 (07) : 1211 - 1223
  • [23] Reference intervals for 10 platelet parameters on Mindray BC-6800 plus hematology analyzer
    Kim, H.
    Hur, M.
    Kim, S.
    Moon, H.
    Yun, Y.
    CLINICA CHIMICA ACTA, 2022, 530 : S180 - S180
  • [24] Precision and accuracy of the Mindray BC-5000Vet hematology analyzer for canine and feline blood
    Thongsahuan, Sorawat
    Fonghoi, Lalita
    Kaewfai, Sunita
    Srinoun, Kanitta
    VETERINARY CLINICAL PATHOLOGY, 2020, 49 (02) : 207 - 216
  • [25] Performance evaluation of the new platelet measurement channel on the BC-6800 Plus automated hematology analyzer
    Guo, Ping
    Cai, Qi
    Mao, Minjing
    Lin, Han
    Chen, Liting
    Wu, Fang
    Wang, Jianbiao
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2022, 44 (02) : 281 - 287
  • [26] Reference intervals for clinically reportable platelet parameters on the Mindray BC-6800Plus hematology analyzer
    Kim, Hanah
    Hur, Mina
    Kim, Seung-Wan
    Moon, Hee-Won
    Yun, Yeo-Min
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (10) : E213 - E215
  • [27] Automated nucleated red blood cell count using the Mindray BC-6800 hematology analyzer
    Houyhongthong, V.
    Nunphuak, W.
    Sripatumtong, C.
    Parnsamut, C.
    Ketloy, C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (05) : 611 - 616
  • [28] Evaluation of the reticulocyte counting by the Mindray BC 6800 automated hematology analyzer: comparison with ABX Pentra 120, Coulter LH 750, and microscopy
    Grillone, R.
    Grimaldi, E.
    Scopacasa, F.
    Conticelli, M.
    Dente, B.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (01) : e3 - e6
  • [29] AUTOMATED SCREENING FOR MALARIA PARASITES ON MINDRAY BC-6800 HEMATOLOGY ANALYZER: A FOLLOW-UP REPORT
    Bhide, Milind
    Parekh, Vijay
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 : 80 - 81
  • [30] Performance evaluation of the new hematology analyzer UniCel DxH 900
    Martinez-Iribarren, Alicia
    Tejedor, Xavier
    Sala Sanjaume, Angels
    Leis, Alba
    Dolade Botias, Maria
    Morales-Indiano, Cristian
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (04) : 623 - 631