Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media

被引:71
|
作者
Szymanowski, H [1 ]
Oelfke, U [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Med Phys E0400, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 18期
关键词
D O I
10.1088/0031-9155/47/18/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
New dose delivery techniques with proton beams, such as beam spot scanning or raster scanning, require fast and accurate dose algorithms which can be applied for treatment plan optimization in clinically acceptable timescales. The clinically required accuracy is particularly difficult to achieve for the irradiation of complex, heterogeneous regions of the patient's anatomy. Currently applied fast pencil beam dose calculations based on the standard inhomogeneity correction of pathlength scaling often cannot provide the accuracy required for clinically acceptable dose distributions. This could be achieved with sophisticated Monte Carlo simulations which are still unacceptably time consuming for use as dose engines in optimization calculations. We therefore present a new algorithm for proton dose calculations which aims to resolve the inherent problem between calculation speed and required clinical accuracy. First, a detailed derivation of the new concept, which is based on an additional scaling of the lateral proton fluence is provided. Then, the newly devised two-dimensional (2D) scaling method is tested for various geometries of different phantom materials. These include standard biological tissues such as bone, muscle and fat as well as air. A detailed comparison of the new 2D pencil beam scaling with the current standard pencil beam approach and Monte Carlo simulations, performed with GEANT, is presented. It was found that the new concept proposed allows calculation of absorbed dose with an accuracy almost equal to that achievable with Monte Carlo simulations while requiring only modestly increased calculation times in comparison to the standard pencil beam approach. It is believed that this new proton dose algorithm has the potential to significantly improve the treatment planning outcome for many clinical cases encountered in highly conformal proton therapy.
引用
收藏
页码:3313 / 3330
页数:18
相关论文
共 50 条
  • [31] Asymptotic behavior of the capacity in two-dimensional heterogeneous media
    Braides, Andrea
    Brusca, Giuseppe Cosma
    RENDICONTI LINCEI-MATEMATICA E APPLICAZIONI, 2023, 34 (02) : 383 - 399
  • [32] Two-dimensional time-resolved scintillating sheet monitoring of proton pencil beam scanning FLASH mouse irradiations
    Kanouta, Eleni
    Bruza, Petr
    Johansen, Jacob Graversen
    Kristensen, Line
    Sorensen, Brita Singers
    Poulsen, Per Rugaard
    MEDICAL PHYSICS, 2024, 51 (07) : 5119 - 5129
  • [33] PENCIL BEAM FOR ELECTRON INTRAOPERATIVE RADIOTHERAPY. RESULTS OF DOSE CALCULATIONS IN HETEROGENEOUS MEDIA.
    Calama Santiago, J. A.
    Garcia-Romero, A.
    Lardies Fleta, D.
    Infante Utrilla, M. A.
    Lopez Tarjuelo, J.
    Ferrer Albiach, C.
    Serrano Navarro, C.
    Lavado Rodriguez, E.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S13 - S13
  • [34] A PENCIL BEAM ALGORITHM FOR HELIUM ION BEAM DOSE CALCULATION
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S39 - S40
  • [35] Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients
    Maes, D.
    Bowen, S. R.
    Fung, A.
    Saini, J.
    Bloch, C.
    Egan, A.
    Zeng, J.
    Rengan, R.
    Wong, T. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E694 - E694
  • [36] Verification of a proton treatment-planning pencil-beam dose algorithm with Monte Carlo
    Titt, U.
    Zheng, Y.
    Zhu, X.
    Mohan, R.
    Newhauser, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2149 - 2149
  • [37] A scaling analysis of electronic localization in two-dimensional random media
    Ye, Z
    PHYSICS LETTERS A, 2003, 319 (3-4) : 416 - 423
  • [38] Beam propagation in two-dimensional media with spatial dispersion
    Dai, Zhiping
    Xu, Yi
    Guo, Qi
    Chi, Sien
    PHYSICAL REVIEW A, 2013, 87 (05):
  • [39] Implementations of the generalised Gaussian pencil beam algorithm for three-dimensional electron beam dose planning
    Hyodynmaa, Simo
    Publications - Technical Research Centre of Finland, 1991, (74): : 1 - 96
  • [40] VERIFICATION OF A 2-DIMENSIONAL PENCIL BEAM ARC ELECTRON DOSE CALCULATION ALGORITHM
    ANTOLAK, JA
    ELKHATIB, E
    SCRIMGER, JW
    MEDICAL PHYSICS, 1993, 20 (06) : 1735 - 1742