Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media

被引:71
|
作者
Szymanowski, H [1 ]
Oelfke, U [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Med Phys E0400, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 18期
关键词
D O I
10.1088/0031-9155/47/18/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
New dose delivery techniques with proton beams, such as beam spot scanning or raster scanning, require fast and accurate dose algorithms which can be applied for treatment plan optimization in clinically acceptable timescales. The clinically required accuracy is particularly difficult to achieve for the irradiation of complex, heterogeneous regions of the patient's anatomy. Currently applied fast pencil beam dose calculations based on the standard inhomogeneity correction of pathlength scaling often cannot provide the accuracy required for clinically acceptable dose distributions. This could be achieved with sophisticated Monte Carlo simulations which are still unacceptably time consuming for use as dose engines in optimization calculations. We therefore present a new algorithm for proton dose calculations which aims to resolve the inherent problem between calculation speed and required clinical accuracy. First, a detailed derivation of the new concept, which is based on an additional scaling of the lateral proton fluence is provided. Then, the newly devised two-dimensional (2D) scaling method is tested for various geometries of different phantom materials. These include standard biological tissues such as bone, muscle and fat as well as air. A detailed comparison of the new 2D pencil beam scaling with the current standard pencil beam approach and Monte Carlo simulations, performed with GEANT, is presented. It was found that the new concept proposed allows calculation of absorbed dose with an accuracy almost equal to that achievable with Monte Carlo simulations while requiring only modestly increased calculation times in comparison to the standard pencil beam approach. It is believed that this new proton dose algorithm has the potential to significantly improve the treatment planning outcome for many clinical cases encountered in highly conformal proton therapy.
引用
收藏
页码:3313 / 3330
页数:18
相关论文
共 50 条
  • [11] Implementation of apertures in a proton pencil-beam dose algorithm
    Depauw, N.
    Kooy, H. M.
    Daartz, J.
    Bussiere, M.
    Batin, E.
    Madden, T.
    Williams, M.
    Schueman, J.
    Clasie, B. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [12] A new pencil beam model for photon dose calculations in heterogeneous media
    Zhang, P.
    Simon, A.
    De Crevoisier, R.
    Haigron, P.
    Nassef, M. H.
    Li, B.
    Shu, H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 765 - 773
  • [13] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Meng-Ya Guo
    Xiu-Fang Li
    Jie Wang
    Qi Liu
    Xiu-Zhen Deng
    Man-Zhou Zhang
    Li-Ren Shen
    Yue-Hu Pu
    Zhi-Ling Chen
    Nuclear Science and Techniques, 2021, 32 (06) : 85 - 95
  • [14] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Guo, Meng-Ya
    Li, Xiu-Fang
    Wang, Jie
    Liu, Qi
    Deng, Xiu-Zhen
    Zhang, Man-Zhou
    Shen, Li-Ren
    Pu, Yue-Hu
    Chen, Zhi-Ling
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (06)
  • [15] Range-modulated pencil beam algorithm for proton dose calculations
    Kohno, R
    Takada, Y
    Sakae, T
    Nohtomi, A
    Terunuma, T
    Matsumoto, K
    Matsuda, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (08): : 5187 - 5193
  • [16] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Meng-Ya Guo
    Xiu-Fang Li
    Jie Wang
    Qi Liu
    Xiu-Zhen Deng
    Man-Zhou Zhang
    Li-Ren Shen
    Yue-Hu Pu
    Zhi-Ling Chen
    Nuclear Science and Techniques, 2021, 32
  • [17] Range-modulated pencil beam algorithm for proton dose calculations
    Kohno, R.
    Takada, Y.
    Sakae, T.
    Nohtomi, A.
    Terunuma, T.
    Matsumoto, K.
    Matsuda, H.
    2001, Japan Society of Applied Physics (40):
  • [18] Pencil Beam Dose Algorithm for Intensity Modulated Proton Therapy with Scanning Proton Beams
    Wang, H.
    Zheng, H.
    Cao, R.
    Jia, J.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [19] A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media
    Tillikainen, L.
    Helminen, H.
    Torsti, T.
    Siljamaki, S.
    Alakuijala, J.
    Pyyry, J.
    Ulmer, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3821 - 3839
  • [20] Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
    Lin, Liyong
    Kang, Minglei
    Solberg, Timothy D.
    Mertens, Thierry
    Baumer, Christian
    Ainsley, Christopher G.
    McDonough, James E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 270 - 276