Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning

被引:0
|
作者
Meng-Ya Guo
Xiu-Fang Li
Jie Wang
Qi Liu
Xiu-Zhen Deng
Man-Zhou Zhang
Li-Ren Shen
Yue-Hu Pu
Zhi-Ling Chen
机构
[1] Chinese Academy of Sciences,Shanghai Institute of Applied Physics
[2] University of Chinese Academy of Sciences,undefined
[3] Shanghai APACTRON Particle Equipment Co. Ltd,undefined
[4] Shanghai Advanced Research Institute,undefined
[5] Chinese Academy of Sciences,undefined
来源
关键词
2D ion chamber array detectors; Laplacian pyramid image blending; High-resolution reformatted methods; Pencil beam scanning; Proton therapy;
D O I
暂无
中图分类号
学科分类号
摘要
The spatial resolution of a commercial two-dimensional (2D) ionization chamber (IC) array is limited by the size of the individual detector and the center-to-center distance between sensors. For dose distributions with areas of steep dose gradients, inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements. This may introduce significant errors, particularly in proton spot scanning radiotherapy. In this study, by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method, a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution. Meanwhile, the similarity between the measured original data and the downsampled logfile-based reconstructed dose is regarded as the confidence of the reformatted dose distribution. Furthermore, we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements. The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements. The reformatted dose distributions generally yield a confidence exceeding 95%.
引用
收藏
相关论文
共 50 条
  • [1] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Guo, Meng-Ya
    Li, Xiu-Fang
    Wang, Jie
    Liu, Qi
    Deng, Xiu-Zhen
    Zhang, Man-Zhou
    Shen, Li-Ren
    Pu, Yue-Hu
    Chen, Zhi-Ling
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (06)
  • [2] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Meng-Ya Guo
    Xiu-Fang Li
    Jie Wang
    Qi Liu
    Xiu-Zhen Deng
    Man-Zhou Zhang
    Li-Ren Shen
    Yue-Hu Pu
    Zhi-Ling Chen
    Nuclear Science and Techniques, 2021, 32 (06) : 85 - 95
  • [3] Experimental Characterization of Two-Dimensional Pencil Beam Scanning Proton Spot Profiles
    Lin, L.
    Ainsley, C.
    McDonough, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Experimental characterization of two-dimensional pencil beam scanning proton spot profiles
    Lin, Liyong
    Ainsley, Christopher G.
    McDonough, James E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (17): : 6193 - 6204
  • [5] Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzles
    Lin, Liyong
    Ainsley, Christopher G.
    Solberg, Timothy D.
    McDonough, James E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 493 - 504
  • [6] Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
    Lin, Liyong
    Kang, Minglei
    Solberg, Timothy D.
    Mertens, Thierry
    Baumer, Christian
    Ainsley, Christopher G.
    McDonough, James E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 270 - 276
  • [7] Comparison of Beam Data for Two Varian ProBeam Pencil Beam Scanning Proton Systems
    Langner, U.
    Langen, K.
    Eley, J.
    Zhu, M.
    Yu, J.
    Chung, H.
    Polf, J.
    Dong, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3499 - 3499
  • [8] Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays
    Kim, M.
    Son, J.
    Hwang, U.
    Shin, D.
    Park, J.
    Lim, Y.
    Lee, S.
    Kim, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 382 - 382
  • [9] Golden beam data for proton pencil-beam scanning
    Clasie, Benjamin
    Depauw, Nicolas
    Fransen, Maurice
    Goma, Carles
    Panahandeh, Hamid Reza
    Seco, Joao
    Flanz, Jacob B.
    Kooy, Hanne M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1147 - 1158
  • [10] Two-dimensional time-resolved scintillating sheet monitoring of proton pencil beam scanning FLASH mouse irradiations
    Kanouta, Eleni
    Bruza, Petr
    Johansen, Jacob Graversen
    Kristensen, Line
    Sorensen, Brita Singers
    Poulsen, Per Rugaard
    MEDICAL PHYSICS, 2024, 51 (07) : 5119 - 5129