Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning

被引:0
|
作者
Meng-Ya Guo
Xiu-Fang Li
Jie Wang
Qi Liu
Xiu-Zhen Deng
Man-Zhou Zhang
Li-Ren Shen
Yue-Hu Pu
Zhi-Ling Chen
机构
[1] Chinese Academy of Sciences,Shanghai Institute of Applied Physics
[2] University of Chinese Academy of Sciences,undefined
[3] Shanghai APACTRON Particle Equipment Co. Ltd,undefined
[4] Shanghai Advanced Research Institute,undefined
[5] Chinese Academy of Sciences,undefined
来源
关键词
2D ion chamber array detectors; Laplacian pyramid image blending; High-resolution reformatted methods; Pencil beam scanning; Proton therapy;
D O I
暂无
中图分类号
学科分类号
摘要
The spatial resolution of a commercial two-dimensional (2D) ionization chamber (IC) array is limited by the size of the individual detector and the center-to-center distance between sensors. For dose distributions with areas of steep dose gradients, inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements. This may introduce significant errors, particularly in proton spot scanning radiotherapy. In this study, by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method, a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution. Meanwhile, the similarity between the measured original data and the downsampled logfile-based reconstructed dose is regarded as the confidence of the reformatted dose distribution. Furthermore, we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements. The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements. The reformatted dose distributions generally yield a confidence exceeding 95%.
引用
收藏
相关论文
共 50 条
  • [21] CT calibration for two-dimensional scaling of proton pencil beams
    Szymanowski, H
    Oelfke, U
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (07): : 861 - 874
  • [22] An Overview of the Commissioning of a Two-Gantry Proton Pencil Beam Scanning System
    Zhang, Y.
    Lee, E.
    Xiao, Z.
    Lamba, M.
    Mascia, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2870 - 2870
  • [23] A comparison of two pencil beam scanning treatment planning systems for proton therapy
    Langner, Ulrich W.
    Mundis, Michelle
    Strauss, Dan
    Zhu, Mingyao
    Mossahebi, Sina
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 156 - 163
  • [24] Looking at the output of two-dimensional motion detector arrays
    Zanker, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3398 - 3398
  • [25] Development of a new 3-dimensional scintillating detector for patient treatment quality control in pencil beam scanning proton therapy
    Frelin, Anne-Marie
    Daviau, G.
    Bui, My Hoang Hoa
    Fontbonne, Cathy
    Fontbonne, Jean-Marc
    Lebhertz, Dorothee
    Mainguy, Erwan
    Moignier, Cyril
    Vela, Anthony
    Thariat, Juliette
    13TH INTERNATIONAL CONFERENCE ON 3D DOSIMETRY, IC3DDOSE 2024, 2024, 2799
  • [26] Considering the constraints of delivery method in treatment planning for proton pencil beam scanning
    Trofimov, A
    Bortfeld, T
    Jennekens, W
    MEDICAL PHYSICS, 2003, 30 (06) : 1447 - 1448
  • [27] A method for proton pencil beam scanning treatment fraction and course integrity QA
    Marmitt, G. Guterres
    Pin, A.
    Hengeveld, A.
    Ribeiro, C. O.
    Langendijk, J. A.
    Both, S.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1431 - S1432
  • [28] Proton Pencil Beam Scanning for Mediastinal Lymphoma: 4-Dimensional Feasibility Study
    Zeng, C.
    Plastaras, J.
    Tochner, Z.
    Hill-Kayser, C.
    Hahn, S.
    Both, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 285 - +
  • [29] On the dynamics of two-dimensional array beam scanning via perimeter detuning of coupled oscillator arrays
    Pogorzelski, RJ
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2001, 49 (02) : 234 - 242
  • [30] Beam steering with pulsed two-dimensional transducer arrays
    Turnbull, Daniel H., 1600, (38):