Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning

被引:0
|
作者
Meng-Ya Guo
Xiu-Fang Li
Jie Wang
Qi Liu
Xiu-Zhen Deng
Man-Zhou Zhang
Li-Ren Shen
Yue-Hu Pu
Zhi-Ling Chen
机构
[1] Chinese Academy of Sciences,Shanghai Institute of Applied Physics
[2] University of Chinese Academy of Sciences,undefined
[3] Shanghai APACTRON Particle Equipment Co. Ltd,undefined
[4] Shanghai Advanced Research Institute,undefined
[5] Chinese Academy of Sciences,undefined
来源
关键词
2D ion chamber array detectors; Laplacian pyramid image blending; High-resolution reformatted methods; Pencil beam scanning; Proton therapy;
D O I
暂无
中图分类号
学科分类号
摘要
The spatial resolution of a commercial two-dimensional (2D) ionization chamber (IC) array is limited by the size of the individual detector and the center-to-center distance between sensors. For dose distributions with areas of steep dose gradients, inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements. This may introduce significant errors, particularly in proton spot scanning radiotherapy. In this study, by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method, a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution. Meanwhile, the similarity between the measured original data and the downsampled logfile-based reconstructed dose is regarded as the confidence of the reformatted dose distribution. Furthermore, we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements. The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements. The reformatted dose distributions generally yield a confidence exceeding 95%.
引用
收藏
相关论文
共 50 条
  • [41] Generation of two-dimensional multicolored arrays and their weak beam control
    Wu, Kun
    Xu, Han
    Wu, Jian
    Zeng, He-Ping
    Wuli Xuebao/Acta Physica Sinica, 2007, 56 (12): : 6999 - 7008
  • [42] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [43] THE MEASUREMENT OF THE TWO-DIMENSIONAL POTENTIAL DISTRIBUTION IN INTEGRATED-CIRCUITS BY THE METHOD OF LASER SCANNING
    ANGELOVA, LA
    KRAVCHENKO, LN
    SAGIYAN, GM
    KVANTOVAYA ELEKTRONIKA, 1988, 15 (08): : 1676 - 1680
  • [44] Development of Optical Fiber Based Measurement System for the Verification of Entrance Dose Map in Pencil Beam Scanning Proton Beam
    Son, Jaeman
    Lee, Se Byeong
    Lim, Youngkyung
    Park, Sung Yong
    Cho, Kwanho
    Yoon, Myonggeun
    Shin, Dongho
    SENSORS, 2018, 18 (01):
  • [45] A New Method for Rapid Reconstruction of Patient Neutron Dose in Pencil Beam Scanning Proton Treatment
    Yeom, Y.
    Griffin, K.
    Mille, M.
    Jung, J.
    Lee, C.
    Lee, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E338 - E338
  • [46] Impact of respiratory motion on proton pencil beam scanning FLASH radiotherapy: an in silico and phantom measurement study
    Yang, Yunjie
    Kang, Minglei
    Huang, Sheng
    Chen, Chin-Cheng
    Tsai, Pingfang
    Hu, Lei
    Yu, Francis
    Hajj, Carla
    Choi, J. Isabelle
    Tome, Wolfgang A.
    Simone II, Charles B.
    Lin, Haibo
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08):
  • [47] Proton Pencil Beam Scanning for Mediastinal Lymphoma: Dosimetric Evaluation and 4-Dimensional Robustness Assessment
    Zeng, C.
    Plastaras, J. P.
    James, P.
    Tochner, Z. A.
    Hill-Kayser, C. E.
    Hahn, S. M.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S922 - S922
  • [48] Three-dimensional dosimetry using multiple-energy delivery and a single-layer detector for quality assurance in proton pencil beam scanning
    Righetto, Roberto
    Fogazzi, Elena
    Tommasino, Francesco
    Farace, Paolo
    MEDICAL PHYSICS, 2025, 52 (03) : 1769 - 1778
  • [49] Measurement of stray neutron doses inside the treatment room from a proton pencil beam scanning system
    Mojzeszek, N.
    Farah, J.
    Klodowska, M.
    Ploc, O.
    Stolarczyk, L.
    Waligorski, M. P. R.
    Olko, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 80 - 84
  • [50] Estimation of two-dimensional frequencies using modified matrix pencil method
    Chen, Fang-Jiong
    Fung, Carrson C.
    Kok, Chi-Wah
    Kwong, Sam
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2007, 55 (02) : 718 - 724