Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice

被引:100
|
作者
Burnstein, Y [1 ]
Ellish, NJ [1 ]
Magbalon, M [1 ]
Higginbotham, EJ [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Ophthalmol, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0002-9394(99)00364-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the sensitivity and specificity of frequency doubling perimetry with Humphrey visual field testing used as the gold standard. METHODS: Frequency doubling perimetry and Humphrey visual field testing (24-2) were performed on 29 consecutive patients in a glaucoma practice. Data for the right eye were used to calculate sensitivity, specificity, and receiver operating characteristic curves. RESULTS: For the frequency doubling perimetry in screening mode, and with an abnormal glaucoma hemifield test used as the gold standard, the area under the receiver operating characteristic curve was 89.3%, 81.5%, or 75.0% for the presence of mild, moderate, or severe relative defects, respectively. Similar results were found with the use of mean deviation (P < .05) to define Humphrey visual field defects. For frequency doubling perimetry in threshold mode, the area under the receiver operating characteristic curve was 93.4% with the presence of any defect (P < .05) used as the criterion for an abnormal case, and an abnormal glaucoma hemifield test as the gold standard. In all cases, the threshold mode detected defects better than the screening mode. CONCLUSIONS: Frequency doubling perimetry showed a high sensitivity and specificity for detecting visual field abnormalities, especially when threshold strategies were used. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 50 条
  • [31] The influence of instruction on frequency doubling technology perimetry and Humphrey Matrix results in normals and early glaucoma patients
    Takahashi, G
    Aoki, Y
    Koike, T
    Nakano, T
    Kitahara, K
    Demirel, S
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [32] Comparison of frequency doubling and flicker defined form perimetry in early glaucoma
    Horn, Folkert K.
    Scharch, Vicki
    Mardin, Christian Y.
    Laemmer, Robert
    Kremers, Jan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (05) : 937 - 946
  • [33] Comparison of Web-based Perimetry and office-based Humphrey Visual Field (HVF) in Patients with Glaucoma
    Hou, Jing
    Wang, Sean
    Keenan, Jeremy
    Chon, Brian
    Subramanian, Nita
    Ianchulev, Tsontcho
    Stamper, Robert
    Chang, Robert
    Han, Ying
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [34] Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma
    Pierre-Filho, Paulo De Tarso
    Gomes, Paulo R. P.
    Pierre, Erika T. L.
    Pierre, Leandro M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 538 - 541
  • [35] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [36] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    Scientific Reports, 12
  • [37] PERIPHERAL VISUAL-FIELD TESTING IN GLAUCOMA BY AUTOMATED KINETIC PERIMETRY WITH THE HUMPHREY FIELD ANALYZER
    BALLON, BJ
    ECHELMAN, DA
    SHIELDS, MB
    OLLIE, AR
    ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (12) : 1730 - 1732
  • [38] Performance of frequency doubling perimetry in screening for glaucoma
    Weih, L
    Sakellariou, A
    Rait, J
    McCarty, C
    Taylor, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S477 - S477
  • [39] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [40] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69