Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma

被引:6
|
作者
Pierre-Filho, Paulo De Tarso [1 ]
Gomes, Paulo R. P. [1 ]
Pierre, Erika T. L. [1 ]
Pierre, Leandro M. [1 ]
机构
[1] Santa Casa Sobral, Dept Ophthalmol, Sobral, Brazil
关键词
Glaucoma; Learning effect; Matrix; Perimetry; Visual field; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; VARIABILITY; THRESHOLD; PATTERN;
D O I
10.1177/112067211002000328
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the learning effect of frequency doubling technology (FDT) perimetry using the Humphrey Matrix perimeter in patients with open-angle glaucoma with no perimetric experience. Methods. One eye each of 30 glaucoma patients who had no history of visual field testing underwent 3 Matrix tests using 24-2 program with full-threshold strategy. The parameters investigated to detect learning effect were test duration, reliability indexes, mean deviation (MD), pattern standard deviation (PSD), and the number of points with a p of <5% and <1% in the total and pattern deviation maps. Results. MD showed a larger defect at the first test (-13.64 +/- 1.63 dB) than at the second (-12.68 +/- 1.45 dB) and third (-11.69 +/- 1.48 dB) tests (p<0.05). A statistically significant reduction (p<0.05) in the number of points with a p <5% and <1% in the total deviation map was observed when repeating the examination. The values of test duration, PSD, fixation losses, false-positive rate, false-negative rate, and number of points with a p <5% and <1% in the pattern deviation map were not changed significantly (p>0.05). Conclusions. Humphrey Matrix FDT perimetry showed a statistically significant learning effect on MD and the number of significantly depressed points of the total deviation map in glaucoma patients with no perimetric experience. It is probably necessary to obtain at least 3 repetitions to rule out the presence of a learning effect in such patients before providing useful results. (Eur J Ophthalmol 2010; 20: 538-41)
引用
收藏
页码:538 / 541
页数:4
相关论文
共 50 条
  • [1] Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma
    Clement, C. I.
    Goldberg, I.
    Healey, P. R.
    Graham, S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 582 - 588
  • [2] Learning effect and measurement variability in frequency-doubling technology perimetry in chronic open-angle glaucoma
    Matsuo, H
    Tomita, G
    Suzuki, Y
    Araie, M
    JOURNAL OF GLAUCOMA, 2002, 11 (06) : 467 - 473
  • [3] Learning effect of Humphrey Matrix Frequency Doubling Technology perimetry in patients with ocular hypertension
    Centofanti, Marco
    Fogagnolo, Paolo
    Oddone, Francesco
    Orzalesi, Nicola
    Vetrugno, Michele
    Manni, Gianluca
    Rossetti, Luca
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 436 - 441
  • [4] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [5] The influence of instruction on frequency doubling technology perimetry and Humphrey Matrix results in normals and early glaucoma patients
    Takahashi, G
    Aoki, Y
    Koike, T
    Nakano, T
    Kitahara, K
    Demirel, S
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Frequency doubling technology C20.5 versus Humphrey 24.2 in ocular hypertension and open-angle glaucoma
    May, F
    Renard, JP
    Maurin, JF
    PERIMETRY UPDATE 2000/2001, 2001, : 201 - 207
  • [7] Learning effect for frequency doubling perimetry in patients with glaucoma
    Fujimoto, N
    Minowa, K
    Miyauchi, O
    Hanawa, T
    Adachi-Usami, E
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (02) : 269 - 270
  • [8] Comparison of the effectiveness of frequency doubling technology perimetry in detecting abnormalities in primary open-angle glaucoma and normal-tension glaucoma
    Osako, M
    Horikoshi, N
    Tamura, Y
    Okano, T
    Usui, M
    PERIMETRY UPDATE 2000/2001, 2001, : 315 - 315
  • [9] The influence of learning effect on frequency doubling technology perimetry (Matrix)
    Contestabile, Maria Teresa
    Perdicchi, Andrea
    Amodeo, Stefano
    Recupero, Vincenzo
    Recupero Santi, Maria
    JOURNAL OF GLAUCOMA, 2007, 16 (03) : 297 - 301
  • [10] Learning effect in visual field testing of healthy subjects using Humphrey Matrix frequency doubling technology perimetry
    Pierre-Filho, P. de T.
    Gomes, P. R.
    Pierre, E. T.
    Pierre, L. M.
    EYE, 2010, 24 (05) : 851 - 856