Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma

被引:6
|
作者
Pierre-Filho, Paulo De Tarso [1 ]
Gomes, Paulo R. P. [1 ]
Pierre, Erika T. L. [1 ]
Pierre, Leandro M. [1 ]
机构
[1] Santa Casa Sobral, Dept Ophthalmol, Sobral, Brazil
关键词
Glaucoma; Learning effect; Matrix; Perimetry; Visual field; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; VARIABILITY; THRESHOLD; PATTERN;
D O I
10.1177/112067211002000328
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the learning effect of frequency doubling technology (FDT) perimetry using the Humphrey Matrix perimeter in patients with open-angle glaucoma with no perimetric experience. Methods. One eye each of 30 glaucoma patients who had no history of visual field testing underwent 3 Matrix tests using 24-2 program with full-threshold strategy. The parameters investigated to detect learning effect were test duration, reliability indexes, mean deviation (MD), pattern standard deviation (PSD), and the number of points with a p of <5% and <1% in the total and pattern deviation maps. Results. MD showed a larger defect at the first test (-13.64 +/- 1.63 dB) than at the second (-12.68 +/- 1.45 dB) and third (-11.69 +/- 1.48 dB) tests (p<0.05). A statistically significant reduction (p<0.05) in the number of points with a p <5% and <1% in the total deviation map was observed when repeating the examination. The values of test duration, PSD, fixation losses, false-positive rate, false-negative rate, and number of points with a p <5% and <1% in the pattern deviation map were not changed significantly (p>0.05). Conclusions. Humphrey Matrix FDT perimetry showed a statistically significant learning effect on MD and the number of significantly depressed points of the total deviation map in glaucoma patients with no perimetric experience. It is probably necessary to obtain at least 3 repetitions to rule out the presence of a learning effect in such patients before providing useful results. (Eur J Ophthalmol 2010; 20: 538-41)
引用
收藏
页码:538 / 541
页数:4
相关论文
共 50 条
  • [41] Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy
    Spry, PGD
    Hussin, HM
    Sparrow, JM
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (08) : 1031 - 1035
  • [42] FREQUENCY OF HLA ANTIGENS IN GREEK PATIENTS WITH OPEN-ANGLE GLAUCOMA
    GABRIEL, L
    RENIERI, N
    STAVROPOULOS, C
    OPHTHALMOLOGICA, 1981, 182 (01) : 49 - 53
  • [43] Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma
    Artes, PH
    Hutchison, DM
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2451 - 2457
  • [44] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [45] Frequency Doubling Technology Perimetry and Changes in Quality of Life of Glaucoma Patients: A Longitudinal Study
    Abe, Ricardo Y.
    Gracitelli, Carolina P. B.
    Diniz-Filho, Alberto
    Zangwill, Linda M.
    Weinreb, Robert N.
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (01) : 114 - 122
  • [46] Screening with frequency doubling technology perimetry: Do subjects with glaucoma demonstrate a teaming effect?
    Brush, MB
    Chen, PP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U492 - U492
  • [47] EFFECT OF CLOFIBRATE ON OPEN-ANGLE GLAUCOMA
    MARRS, JM
    ROWE, KW
    ARCHIVES OF OPHTHALMOLOGY, 1969, 82 (01) : 19 - &
  • [48] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Serguhn, S
    Spiegel, D
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 351 - 355
  • [49] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [50] Diagnosing glaucoma from frequency doubling technology perimetry using supervised machine learning classifiers
    Pascual, JP
    Zhang, Z
    Hughes, AJ
    Hao, J
    Lee, TW
    Sejnowski, T
    Goldbaum, MH
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U780 - U780