Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice

被引:100
|
作者
Burnstein, Y [1 ]
Ellish, NJ [1 ]
Magbalon, M [1 ]
Higginbotham, EJ [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Ophthalmol, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0002-9394(99)00364-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the sensitivity and specificity of frequency doubling perimetry with Humphrey visual field testing used as the gold standard. METHODS: Frequency doubling perimetry and Humphrey visual field testing (24-2) were performed on 29 consecutive patients in a glaucoma practice. Data for the right eye were used to calculate sensitivity, specificity, and receiver operating characteristic curves. RESULTS: For the frequency doubling perimetry in screening mode, and with an abnormal glaucoma hemifield test used as the gold standard, the area under the receiver operating characteristic curve was 89.3%, 81.5%, or 75.0% for the presence of mild, moderate, or severe relative defects, respectively. Similar results were found with the use of mean deviation (P < .05) to define Humphrey visual field defects. For frequency doubling perimetry in threshold mode, the area under the receiver operating characteristic curve was 93.4% with the presence of any defect (P < .05) used as the criterion for an abnormal case, and an abnormal glaucoma hemifield test as the gold standard. In all cases, the threshold mode detected defects better than the screening mode. CONCLUSIONS: Frequency doubling perimetry showed a high sensitivity and specificity for detecting visual field abnormalities, especially when threshold strategies were used. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 50 条
  • [21] Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
    Rajalakshmi, A. R.
    Suma, Elangovan
    Prabhu, D. Ranjit
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (07) : NC01 - NC03
  • [22] Visual Field Progression With Frequency-Doubling Matrix Perimetry and Standard Automated Perimetry in Patients With Glaucoma and in Healthy Controls
    Redmond, Tony
    O'Leary, Neil
    Hutchison, Donna M.
    Nicolela, Marcelo T.
    Artes, Paul H.
    Chauhan, Balwantray C.
    JAMA OPHTHALMOLOGY, 2013, 131 (12) : 1565 - 1572
  • [23] Comparison of Visual Field Results of Humphrey Matrix Perimetry and Standard Automated Perimetry with SITA Strategy in Glaucoma and Ocular Hypertension Subjects
    Yilmaz, Pinar Topcu
    Bozkurt, Banu
    Irkec, Murat
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 98 - 103
  • [24] A COMPARISON OF GOLDMAN AND HUMPHREY PERIMETRY IN PATIENTS WITH GLAUCOMA
    TROPE, GE
    BRITTAIN, R
    MORTIMER, CB
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1985, 20 (02): : 57 - 57
  • [25] Comparison of results with frequency doubling perimetry and Humphrey C30-2 in eyes with higher normal tension glaucoma.
    Kogure, S
    Toda, Y
    Crabb, D
    Fitzke, F
    Tsukahara, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S87 - S87
  • [26] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice
    Wadood, AC
    Azuara-Blanco, A
    Aspinall, P
    Taguri, A
    King, AJW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (03) : 327 - 332
  • [27] Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss
    Saric, D
    Mandic, Z
    Ivekovic, R
    Geber, MZ
    Bencic, G
    Tomic, Z
    Grgic, D
    COLLEGIUM ANTROPOLOGICUM, 2005, 29 : 111 - 113
  • [28] Localized retinal nerve fiber layer defects and visual field abnormalities by Humphrey matrix frequency doubling technology perimetry
    Lee, Min Joung
    Kim, Dong Myung
    Jeoung, Jin Wook
    Hwang, Seung Sik
    Kim, Tae Woo
    Park, Ki Ho
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1056 - 1058
  • [29] Comparison of frequency doubling and flicker defined form perimetry in early glaucoma
    Folkert K. Horn
    Vicki Scharch
    Christian Y. Mardin
    Robert Lämmer
    Jan Kremers
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 937 - 946
  • [30] Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry
    Landers, JA
    Goldberg, I
    Graham, SL
    ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (12) : 1705 - 1710