Potentiometric flow injection determination of serum bromide in patients with epilepsy

被引:13
|
作者
Katsu, T [1 ]
Mori, Y [1 ]
Matsuka, N [1 ]
Gomita, Y [1 ]
机构
[1] OKAYAMA UNIV,SCH MED,DEPT HOSP PHARM,OKAYAMA 700,JAPAN
关键词
flow injection analysis; ion-selective electrode; bromide; therapeutic drug monitoring; epilepsy;
D O I
10.1016/S0731-7085(96)02017-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system was constructed using a bromide-selective electrode and used to determine serum bromide in patients with epilepsy. A 10-mu l serum sample was injected into a carrier stream flowing at 0.12 mi min(-1). Potential changes and bromide concentrations were linearly related in the range 3-50 mM. The lower limit of detection for serum bromide was 1 mM and this electrode sensitivity spanned the entire concentration range required for bromide therapy (9-24 mM). The results compared favourably with those obtained by colorimetry. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1829 / 1832
页数:4
相关论文
共 50 条
  • [41] Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection
    Jackson S. Albuquerque
    Valdinete L. Silva
    Fernando Lima
    Alberto N. Araújo
    Maria Conceição B. S. M. Montenegro
    Analytical Sciences, 2003, 19 : 691 - 694
  • [42] Potentiometric Determination of Imatinib under Batch and Flow Injection Analysis Conditions
    Karim, Shereen E. Abdel
    El-Nashar, Rasha M.
    Abadi, Ashraf H.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10): : 9668 - 9681
  • [43] Determination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detection
    Andac, Muberra
    Eren, Hilal
    Coldur, Fatih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (04) : 457 - 462
  • [44] OXIDATIVE REMOVAL OF INTERFERENCES IN FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF CHLORIDE
    KRAWCZYK, TKV
    SZOSTEK, B
    TROJANOWICZ, M
    TALANTA, 1989, 36 (08) : 811 - 815
  • [45] Carbon paste and PVC electrodes for the flow injection potentiometric determination of dextromethorphan
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Seleim, A. A.
    TALANTA, 2010, 81 (1-2) : 510 - 515
  • [46] Flow injection differential potentiometric determination of lysine by using a lysine biosensor
    García-Villar, N
    Saurina, J
    Hernández-Cassou, S
    ANALYTICA CHIMICA ACTA, 2003, 477 (02) : 315 - 324
  • [47] Flow injection potentiometric determination of total antioxidant activity of plant extracts
    Shpigun, Liliya K.
    Arharova, Marina A.
    Brainina, Khena Z.
    Ivanova, Alla V.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 419 - 426
  • [48] Polymeric Membrane Sensors for Batch and Flow Injection Potentiometric Determination of Procainamide
    Alrabiah, Haitham
    Homoda, Atef M. A.
    Radowan, Abdellatef A.
    Ezzeldin, Essam
    Mostafa, Gamal A. E.
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4198 - 4208
  • [49] Flow injection system with potentiometric detection for the determination of urea content in milks
    Lima, JLFC
    Delerue-Matos, C
    Vaz, MCVF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (04) : 1386 - 1389