Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection

被引:0
|
作者
Jackson S. Albuquerque
Valdinete L. Silva
Fernando Lima
Alberto N. Araújo
Maria Conceição B. S. M. Montenegro
机构
[1] Department of Chemical Engineering/Environmental Engineering and Quality Laboratory-UFPE,CEQUP/Department of Physical Chemistry
[2] Faculty of Pharmacy,undefined
来源
Analytical Sciences | 2003年 / 19卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This work describes an FIA potentiometric procedure for the quantification of dipyrone in pharmaceutical products. For the detector, a tubular electrode comprising a polymeric membrane containing tetraoctylammonium as an electroactive material (5% w/w), dibutylphtalate as a mediator solvent (65% w/w) and PVC (30% w/w) directly applied above a graphite conductor support was used. This unit was incorporated into a monochannel FI-system with a 0.1 mol/L phosphate buffer solution (pH = 5.2) as the carrier solution. The electrode showed a linear response from 8.0 × 10−4 to 10−1 mol/L dipyrone, a slope of 62.1 ± 0.2 mV/dec in pH 5.2 units, an injection volume of 500 μL and a carrier flow-rate of 6 mL/min. This procedure was applied to the analysis of pharmaceutical formulations (oral and injectable) containing dipyrone; the obtained results gave a relative error of less than 3.9% and coefficients of variation less than 1% and 5%, respectively, for the FIA and classical iodometric methods.
引用
收藏
页码:691 / 694
页数:3
相关论文
共 50 条
  • [1] Determination of dipyrone in pharmaceutical products by flow injection analysis with potentiometric detection
    Albuquerque, JS
    Silva, VL
    Lima, F
    Araújo, AN
    Montenegro, MCBSM
    ANALYTICAL SCIENCES, 2003, 19 (05) : 691 - 694
  • [2] Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection - Epinephrine determination in pharmaceutical products
    Amorim, C. G.
    Araujo, A. N.
    Montenegro, M. C. B. S. M.
    TALANTA, 2007, 72 (04) : 1255 - 1260
  • [3] Determination of chloride by multisyringe flow injection analysis and sequential injection analysis with potentiometric detection
    Andrade-Eiroa, A
    Erustes, JA
    Forteza, R
    Cerdá, V
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 25 - 33
  • [4] Determination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detection
    Andac, Muberra
    Eren, Hilal
    Coldur, Fatih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (04) : 457 - 462
  • [5] Simple Flow Injection Amperometric System for Simultaneous Determination of Dipyrone and Paracetamol in Pharmaceutical Formulations
    dos Santos, Wallans T. P.
    Gimenes, Denise T.
    de Almeida, Edimar G. N.
    Eiras, Sebastiao de P.
    Albuquerque, Yaico D. T.
    Richter, Eduardo M.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (07) : 1249 - 1255
  • [6] Flow Injection Spectrophotometric Determination of Dipyrone in Pharmaceutical Formulations Using Fe(III) as Reagent
    Suarez, Willian T.
    Pessoa-Neto, Osmundo D.
    Vicentini, Fernando C.
    Janegitz, Bruno C.
    Faria, Ronaldo C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 340 - 348
  • [7] Flow-injection determination of mercury with potentiometric detection
    Gur'ev, IA
    Kuleshova, NV
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (01) : 15 - 18
  • [8] Flow-Injection Determination of Mercury with Potentiometric Detection
    Gur'ev, I. A.
    Kuleshova, N. V.
    Journal of Analytical Chemistry, 53 (01):
  • [9] Potentiometric flow injection analysis of drotaverine hydrochloride in pharmaceutical preparations
    Ibrahim, H
    Issa, YM
    Abu-Shawish, HM
    ANALYTICAL LETTERS, 2005, 38 (01) : 111 - 132
  • [10] Determination of nitrate in carbon black by flow injection analysis (FIA) with potentiometric detection
    Canal, IG
    Lima, JLFC
    Montenegro, MCBSM
    PrezOlmos, R
    ANALUSIS, 1997, 25 (02) : 32 - 35