Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection

被引:0
|
作者
Jackson S. Albuquerque
Valdinete L. Silva
Fernando Lima
Alberto N. Araújo
Maria Conceição B. S. M. Montenegro
机构
[1] Department of Chemical Engineering/Environmental Engineering and Quality Laboratory-UFPE,CEQUP/Department of Physical Chemistry
[2] Faculty of Pharmacy,undefined
来源
Analytical Sciences | 2003年 / 19卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This work describes an FIA potentiometric procedure for the quantification of dipyrone in pharmaceutical products. For the detector, a tubular electrode comprising a polymeric membrane containing tetraoctylammonium as an electroactive material (5% w/w), dibutylphtalate as a mediator solvent (65% w/w) and PVC (30% w/w) directly applied above a graphite conductor support was used. This unit was incorporated into a monochannel FI-system with a 0.1 mol/L phosphate buffer solution (pH = 5.2) as the carrier solution. The electrode showed a linear response from 8.0 × 10−4 to 10−1 mol/L dipyrone, a slope of 62.1 ± 0.2 mV/dec in pH 5.2 units, an injection volume of 500 μL and a carrier flow-rate of 6 mL/min. This procedure was applied to the analysis of pharmaceutical formulations (oral and injectable) containing dipyrone; the obtained results gave a relative error of less than 3.9% and coefficients of variation less than 1% and 5%, respectively, for the FIA and classical iodometric methods.
引用
收藏
页码:691 / 694
页数:3
相关论文
共 50 条
  • [41] Flow injection analysis of fluoride in electroplating baths with potentiometric detection
    Perez-Olmos, R
    Etxebarria, MB
    Lima, JLFC
    Montenegro, MCBSM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 230 - 233
  • [42] A Novel Membrane Sensor for Batch and Flow Injection Potentiometric Determination of Cefazolin Sodium in Pharmaceutical Preparations
    Badr, Ibrahim H. A.
    Saleh, Gamal A.
    Sayed, Sayed M.
    El-Deen, Deena A. M. Nour
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (04): : 1621 - 1636
  • [43] Novel PVC-membrane electrode for flow injection potentiometric determination of Biperiden in pharmaceutical preparations
    Khaled, Elmorsy
    EI-Sabbagh, Inas A.
    El-Kholy, N. G.
    Ghahni, E. Y. Abdel
    TALANTA, 2011, 87 : 40 - 45
  • [44] Determination of puerarin in pharmaceutical injection by flow injection analysis with acidic potassium permanganate-glyoxal chemiluminescence detection
    Wei, Gaili
    Wei, Chunlong
    Dang, Gaochao
    Yao, Hanchun
    Li, Hua
    ANALYTICAL LETTERS, 2007, 40 (11) : 2179 - 2191
  • [45] FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF SACCHARIN IN DIETARY PRODUCTS WITH RELOCATION OF FILTRATION UNIT
    FATIBELLO-FILHO, O
    NOBREGA, JA
    GUARITASANTOS, AJM
    TALANTA, 1994, 41 (05) : 731 - 734
  • [46] Potentiometric determination of cetylpyridinium chloride in oral desinfectants by flow injection analysis
    Baptista, PCS
    Araújo, AN
    Montenegro, MDBSM
    QUIMICA NOVA, 2003, 26 (04): : 475 - 478
  • [47] FLOW-INJECTION ANALYSIS - POTENTIOMETRIC DETERMINATION OF COPPER(II) IN WATERS
    SHPIGUN, LK
    BAZANOVA, OV
    KUZMIN, NM
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (12): : 1790 - 1795
  • [48] Determination of citric acid in soft drinks using flow injection with potentiometric detection
    José L. F. C. Lima
    C. Delerue-Matos
    M. Carmo
    M. C. V. F. Vaz
    Jeanine Silva
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 266 - 269
  • [49] Determination of citric acid in soft drinks using flow injection with potentiometric detection
    Lima, JLFC
    Delerue-Matos, C
    Carmo, M
    Vaz, VF
    Silva, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03): : 266 - 269
  • [50] Potentiometric Determination of Imatinib under Batch and Flow Injection Analysis Conditions
    Karim, Shereen E. Abdel
    El-Nashar, Rasha M.
    Abadi, Ashraf H.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10): : 9668 - 9681