Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

被引:88
|
作者
Greess, H
Lutze, J
Nömayr, A
Wolf, H
Hothorn, T
Kalender, WA
Bautz, W
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
[2] Siemens AG Med Solut, Forchheim, Germany
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
关键词
multislice spiral CT; mA s reduction; children; image quality; exposure to patients;
D O I
10.1007/s00330-004-2301-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as "very good," "good," "diagnostic" and "poor" in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [31] Dose distribution in conventional CT and spiral CT and the question of dose reduction in spiral CT
    Hidajat, N
    Schroder, RJ
    Vogl, T
    Maurer, J
    Steger, W
    Felix, R
    RADIOLOGE, 1998, 38 (05): : 438 - 443
  • [32] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086
  • [33] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Tobias F. Jakobs
    Christoph R. Becker
    Bernd Ohnesorge
    Thomas Flohr
    Christoph Suess
    Uwe J. Schoepf
    Maximilian F. Reiser
    European Radiology, 2002, 12 : 1081 - 1086
  • [34] Ultra-low-dose multislice spiral CT colonography
    Iannaccone, R
    Laghi, A
    Mangiapane, F
    Trenna, S
    Piacentini, F
    Passariello, R
    RADIOLOGY, 2002, 225 : 585 - 585
  • [35] Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation
    Liu, H.
    Liu, T.
    Xu, X.
    Wu, J.
    Zhuo, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3250 - 3250
  • [36] Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies
    Gies, M
    Kalender, WA
    Wolf, H
    Suess, C
    Madsen, MT
    MEDICAL PHYSICS, 1999, 26 (11) : 2235 - 2247
  • [37] Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
    Kalender, WA
    Wolf, H
    Suess, C
    MEDICAL PHYSICS, 1999, 26 (11) : 2248 - 2253
  • [38] Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
    Herzog, Christopher
    Mulvihill, Denise M.
    Nguyen, Shaun A.
    Savino, Giancarlo
    Schmidt, Bernhard
    Costello, Philip
    Vogl, Thomas J.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1232 - 1240
  • [39] Dose reduction in CT by anatomically adapted tube current modulation: Experimental results and first patient studies
    Kalender, WA
    Wolf, H
    Gies, M
    Hentschel, D
    Bautz, WA
    RADIOLOGY, 1997, 205 : 1398 - 1398
  • [40] Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Damilakis, John
    MEDICAL PHYSICS, 2007, 34 (07) : 2864 - 2874