Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

被引:88
|
作者
Greess, H
Lutze, J
Nömayr, A
Wolf, H
Hothorn, T
Kalender, WA
Bautz, W
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
[2] Siemens AG Med Solut, Forchheim, Germany
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
关键词
multislice spiral CT; mA s reduction; children; image quality; exposure to patients;
D O I
10.1007/s00330-004-2301-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as "very good," "good," "diagnostic" and "poor" in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [21] Dose reduction in body CT examinations by anatomically adapted tube current modulation
    Bautz, WA
    Heim, I
    Wolf, H
    Kalender, WA
    RADIOLOGY, 1997, 205 : 1399 - 1399
  • [22] Bismuth Shielding, Organ-based Tube Current Modulation, and Global Reduction of Tube Current for Dose Reduction to the Eye at Head CT
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Grant, Katharine L.
    McCollough, Cynthia H.
    RADIOLOGY, 2012, 262 (01) : 191 - 198
  • [23] Multi-slice spiral CT angiography of the thoracic outlet: Dose reduction by anatomically-adapted tube current modulation and prospective dose saving
    Mastora, I
    Remy-Jardin, MJ
    Delannoy, V
    Scherf, C
    Suess, C
    Remy, J
    RADIOLOGY, 2001, 221 : 367 - 367
  • [24] Effect of tube current modulation for dose estimation using a simulation tool on body CT examination
    Kawaguchi, Ai
    Matsunaga, Yuta
    Kobayashi, Masanao
    Suzuki, Shoichi
    Matsubara, Kosuke
    Chida, Koichi
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 562 - 568
  • [25] Multislice spiral CT (MSCT) in pediatric radiology:: Dose reduction for chest and abdomen examinations
    Honnef, D
    Wildberger, JE
    Stargardt, A
    Hohl, C
    Barker, M
    Günther, RW
    Staatz, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (07): : 1021 - 1030
  • [26] Dose reduction in spiral CT:: Detection of pulmonary nodules with and without anatomic adaptation of tube current.
    Greess, H
    Baum, U
    Wolf, H
    Lell, M
    Nömayr, A
    Schmidt, B
    Kalender, WA
    Bautz, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05): : 466 - 470
  • [27] A Preliminary Method of Risk-Informed Optimization of Tube Current Modulation for Dose Reduction in CT
    Gao, Y.
    Liu, T.
    Li, X.
    Liu, B.
    Kalra, M.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3622 - 3622
  • [28] Quantitative Effects of Clinical Practice On the Efficiency of CT Tube Current Modulation for Radiation Dose Reduction
    Zhang, J.
    Cornett, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3635 - 3635
  • [29] Dose reduction in spiral CT of the thorax: Detection of pulmonary nodules with and without anatomically adapted current modulation
    Greess, H
    Baum, U
    Lell, M
    Wolf, H
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 1999, 213P : 304 - 304
  • [30] Digital Volume Tomography (DVT) and Multislice Spiral CT (MSCT): an Objective Examination of Dose and Image Quality
    Kyriakou, Y.
    Kolditz, D.
    Langner, O.
    Krause, J.
    Kalender, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (02): : 144 - 153