Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

被引:88
|
作者
Greess, H
Lutze, J
Nömayr, A
Wolf, H
Hothorn, T
Kalender, WA
Bautz, W
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
[2] Siemens AG Med Solut, Forchheim, Germany
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
关键词
multislice spiral CT; mA s reduction; children; image quality; exposure to patients;
D O I
10.1007/s00330-004-2301-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as "very good," "good," "diagnostic" and "poor" in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [1] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    H. Greess
    J. Lutze
    A. Nömayr
    H. Wolf
    T. Hothorn
    W. A. Kalender
    W. Bautz
    European Radiology, 2004, 14 : 995 - 999
  • [2] Dose reduction in subsecond multi-slice spiral CT examinations of children by online tube current modulation
    Greess, H
    Baum, U
    Wolf, H
    Suess, C
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 2001, 221 : 246 - 246
  • [3] Dose reduction in subsecond multi-slice spiral CT by online tube current modulation
    Kalender, WA
    Schmidt, B
    Wolf, H
    Suess, C
    Decker, R
    Greess, H
    RADIOLOGY, 2000, 217 : 487 - 487
  • [4] Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    Holger Greess
    Anton Nömayr
    Heiko Wolf
    Ulrich Baum
    Michael Lell
    Bernhard Böwing
    Willi Kalender
    Werner A. Bautz
    European Radiology, 2002, 12 : 1571 - 1576
  • [5] Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    Greess, H
    Nömayr, A
    Wolf, H
    Baum, U
    Lell, M
    Böwing, B
    Kalender, W
    Bautz, WA
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1571 - 1576
  • [6] Dose reduction in CT examinations of children by anatomically adapted tube current modulation
    Greess, H
    Noemayr, A
    Wolf, H
    Janka, R
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 1999, 213P : 294 - 294
  • [7] Subsecond multislice spiral CT as an alternative to electron beam tomography
    Kalender, WA
    Kachelriess, M
    Ulzheimer, S
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 : 50 - 53
  • [8] Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation
    Mastora, I
    Remy-Jardin, M
    Suess, C
    Scherf, C
    Guillot, JP
    Remy, J
    EUROPEAN RADIOLOGY, 2001, 11 (04) : 590 - 596
  • [9] Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation
    I. Mastora
    M. Remy-Jardin
    C. Suess
    C. Scherf
    J.-P. Guillot
    J. Remy
    European Radiology, 2001, 11 : 590 - 596
  • [10] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334