Manometric biosensor for on-line measurement of milk urea

被引:22
|
作者
Jenkins, DM [1 ]
Delwiche, MJ [1 ]
机构
[1] Univ Calif Davis, Dept Biol & Agr Engn, Davis, CA 95616 USA
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 6-7期
关键词
urease; pressure sensor; animal nutrition; nitrogen balance;
D O I
10.1016/S0956-5663(02)00018-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Performance of a prototype sensor for on-line measurement of urea in milk during milking was evaluated. The sensor was based on a manometric assay of the carbon dioxide generated by the enzymatic hydrolysis of urea. Temperature compensation of the sensor was described briefly, and was shown to be effective. The calibration of the sensor was described and resulted in a standard calibration error of about 0.15 mM of urea. The standard error of the sensor in milk was shown to be about 0.25 mM (given a physiological range of about 2-7 mM in cow milk). The sensor was simple, inexpensive, suffered from no interferences in raw milk, and completed a measurement cycle in about 5 min (less than the time to milk a typical cow). A custom made sampling device, whereby milk was passively collected from the milk line under vacuum, was shown to collect an ample volume within 10 s to run a test with the sensor. No measurable bubbles or foam were introduced from the sampling mechanism so that the milk sampled was not diminished in density compared to samples taken by other methods. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [41] MANOMETRIC MEASUREMENT OF THE GAS DESORBED FROM VACUUMIZED WHOLE MILK POWDER
    HETRICK, JH
    TRACY, PH
    JOURNAL OF DAIRY SCIENCE, 1948, 31 (09) : 831 - 838
  • [42] METHODOLOGICAL STUDIES ON THE MEASUREMENT OF UREA CONTENT IN MILK
    ARNSTADT, KI
    HAAG, T
    ZUCHTHYGIENE-REPRODUCTION IN DOMESTIC ANIMALS, 1984, 19 (03): : 133 - 134
  • [43] The on-line urea sensor: A useful method for hemodialysis prescription
    Almirall, J
    Jurkiewicz, M
    Garcia, M
    Sole, S
    Liesa, A
    Padilla, J
    Yuste, E
    Alegret, S
    MartinezFabregas, E
    NEFROLOGIA, 1996, 16 (06): : 524 - 530
  • [44] An on-line database for human milk composition in China
    Yin, Shi-an
    Yang, Zhen-yu
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2016, 25 (04) : 818 - 825
  • [45] Enzyme immunoassay for on-line sensing of milk progesterone
    Claycomb, RW
    Delwiche, MJ
    Munro, CJ
    BonDurant, RH
    TRANSACTIONS OF THE ASAE, 1996, 39 (02): : 729 - 734
  • [46] Evaluation of pre- and postdilutional on-line hemodiafiltration adequacy by partial dialysate quantification and on-line urea monitor
    Lim, PS
    Lee, HP
    Kho, B
    Yu, YL
    Chang, SC
    Lin, YY
    Yang, CC
    Lin, YT
    Wang, TH
    Kuo, SY
    Lin, LC
    BLOOD PURIFICATION, 1999, 17 (04) : 199 - 205
  • [47] Improved accuracy of on-line tire profile measurement using a novel on-line calibration
    Khalili, K.
    Nazemsadat, S. M.
    PROCEEDINGS OF THE SEVENTH IASTED INTERNATIONAL CONFERENCE ON VISUALIZATION, IMAGING, AND IMAGE PROCESSING, 2007, : 59 - +
  • [48] On-line Measurement of Fiber Diameters along Spinning Line
    Wen, Xin
    Yang, Shenglin
    Li, Guang
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 394 - 399
  • [49] ENHANCED ON-LINE DETECTION FOR RADIOCHEMICAL MEASUREMENT
    Hall, K. A.
    Loaring, H.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2009, 52 (7-8): : 265 - 266
  • [50] On-line oil film thickness measurement
    AMEPA GmbH, Aachen, Germany
    不详
    Iron Steel Technol., 2008, 1 (75-81):