Manometric biosensor for on-line measurement of milk urea

被引:22
|
作者
Jenkins, DM [1 ]
Delwiche, MJ [1 ]
机构
[1] Univ Calif Davis, Dept Biol & Agr Engn, Davis, CA 95616 USA
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 6-7期
关键词
urease; pressure sensor; animal nutrition; nitrogen balance;
D O I
10.1016/S0956-5663(02)00018-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Performance of a prototype sensor for on-line measurement of urea in milk during milking was evaluated. The sensor was based on a manometric assay of the carbon dioxide generated by the enzymatic hydrolysis of urea. Temperature compensation of the sensor was described briefly, and was shown to be effective. The calibration of the sensor was described and resulted in a standard calibration error of about 0.15 mM of urea. The standard error of the sensor in milk was shown to be about 0.25 mM (given a physiological range of about 2-7 mM in cow milk). The sensor was simple, inexpensive, suffered from no interferences in raw milk, and completed a measurement cycle in about 5 min (less than the time to milk a typical cow). A custom made sampling device, whereby milk was passively collected from the milk line under vacuum, was shown to collect an ample volume within 10 s to run a test with the sensor. No measurable bubbles or foam were introduced from the sampling mechanism so that the milk sampled was not diminished in density compared to samples taken by other methods. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [31] Improved biosensor for measurement of progesterone in bovine milk
    Delwiche, Michael
    Tang, Xinkui
    BonDurant, Robert
    Munro, Coralie
    Transactions of the American Society of Agricultural Engineers, 2001, 44 (06): : 1997 - 2002
  • [32] Improving on-line temperature measurement
    Barron, William R.
    Glass International, 1998, 21 (03): : 6 - 8
  • [33] On-line measurement of paint thicknesses
    Petry, Harald
    MO Metalloberflache Beschichten von Metall und Kunststoff, 1998, 52 (04): : 316 - 318
  • [34] On-line moisture measurement by Hydronix
    Board, R
    CANADIAN CERAMICS QUARTERLY-JOURNAL OF THE CANADIAN CERAMIC SOCIETY, 1997, 66 (02): : 99 - 102
  • [35] On-line fault level measurement
    Ibrahim, ES
    Idres, M
    ELECTRIC MACHINES AND POWER SYSTEMS, 1998, 26 (02): : 207 - 217
  • [36] On-line measurement of yarn evenness
    Carvalho, V
    Pinto, JG
    Monteiro, J
    Vasconcelos, RM
    Soares, FO
    2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, : 1059 - 1064
  • [37] Manometric method for the estimation of urea
    Bradbury, FCS
    BRITISH MEDICAL JOURNAL, 1924, 1924 : 275 - 276
  • [38] An on-line respirographic biosensor for the characterization of load and toxicity of wastewaters
    Vanrolleghem, P.A., 1600, John Wiley & Sons Ltd, Chichester, United Kingdom (59):
  • [39] On-line biosensor for the detection of putative toxicity in water contaminants
    Eltzov, Evgeni
    Slobodnik, Vladimir
    Ionescu, Rodica E.
    Marks, Robert S.
    TALANTA, 2015, 132 : 583 - 590
  • [40] On-line determination of nitrite in wastewater treatment by use of a biosensor
    Nielsen, M
    Revsbech, NP
    Larsen, LH
    Lynggaard-Jensen, A
    WATER SCIENCE AND TECHNOLOGY, 2002, 45 (4-5) : 69 - 76