Manometric biosensor for on-line measurement of milk urea

被引:22
|
作者
Jenkins, DM [1 ]
Delwiche, MJ [1 ]
机构
[1] Univ Calif Davis, Dept Biol & Agr Engn, Davis, CA 95616 USA
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 6-7期
关键词
urease; pressure sensor; animal nutrition; nitrogen balance;
D O I
10.1016/S0956-5663(02)00018-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Performance of a prototype sensor for on-line measurement of urea in milk during milking was evaluated. The sensor was based on a manometric assay of the carbon dioxide generated by the enzymatic hydrolysis of urea. Temperature compensation of the sensor was described briefly, and was shown to be effective. The calibration of the sensor was described and resulted in a standard calibration error of about 0.15 mM of urea. The standard error of the sensor in milk was shown to be about 0.25 mM (given a physiological range of about 2-7 mM in cow milk). The sensor was simple, inexpensive, suffered from no interferences in raw milk, and completed a measurement cycle in about 5 min (less than the time to milk a typical cow). A custom made sampling device, whereby milk was passively collected from the milk line under vacuum, was shown to collect an ample volume within 10 s to run a test with the sensor. No measurable bubbles or foam were introduced from the sampling mechanism so that the milk sampled was not diminished in density compared to samples taken by other methods. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [21] A UREA FIBER OPTIC BIOSENSOR BASED ON ABSORPTION MEASUREMENT
    XIE, XF
    SULEIMAN, AA
    GUILBAULT, GG
    ANALYTICAL LETTERS, 1990, 23 (12) : 2143 - 2153
  • [22] Improved biosensor for measurement of progesterone in bovine milk
    Delwiche, M
    Tang, X
    BonDurant, R
    Munro, C
    TRANSACTIONS OF THE ASAE, 2001, 44 (06): : 1997 - 2002
  • [23] Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor
    Palmisano, F
    Quinto, M
    Rizzi, R
    Zambonin, PG
    ANALYST, 2001, 126 (06) : 866 - 870
  • [24] ON-LINE MEASUREMENT OF WATER IN POLYMERS
    COLLIER, GL
    GREEN, RE
    MEASUREMENT AND CONTROL, 1968, 1 (01): : 18 - &
  • [25] On-line measurement of aggregation and flocculation
    Williams, RA
    Jia, X
    HYDROCOLLOIDS, PT 2: FUNDAMENTALS AND APPLICATIONS IN FOOD, BIOLOGY, AND MEDICINE, 1999, : 19 - 28
  • [26] On-line measurement of meat quality
    Meat and Livestock Commission, Winterhill House, Milton Keynes MK6 1AX, United Kingdom
    Food Sci. Technol., 2008, 1 (20-22): : 20 - 22
  • [27] ON-LINE CALIPER MEASUREMENT AND CONTROL
    VANMUNN, PH
    TAPPI, 1970, 53 (05): : 825 - &
  • [28] The Future of Rapid On-Line Measurement
    Watts, Sam
    AMERICAN LABORATORY, 2010, 42 (02) : 34 - +
  • [29] ON-LINE DENSITY-MEASUREMENT
    BALL, AG
    ZELLSTOFF UND PAPIER, 1972, 21 (01): : 25 - &
  • [30] On-line measurement of pickling rates
    Thiele, W.
    MO Metalloberflache Beschichten von Metall und Kunststoff, 1997, 51 (06):