Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy

被引:11
|
作者
Lee, Jaegi [1 ,2 ]
Kim, Jung-In [2 ,3 ,4 ,5 ]
Ye, Sung-Joon [1 ,3 ]
Kim, Hak Jae [3 ,4 ,6 ]
Carlson, Joel [1 ,2 ]
Park, Jong Min [2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Biomed Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[5] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
[6] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1055期
关键词
BODY RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONE-BEAM CT; CANCER; METASTASES; GUIDANCE; POSITION; PATIENT;
D O I
10.1259/bjr.20140862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). Methods: A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by +/- 1 degrees, +/- 2 degrees and +/- 3 degrees. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D-95% and V-100% of the target volume, D-0.35cc of spinal cord, D-0.35cc and D-5cc of oesophagus and V-20Gy of lung between the original and the rotated CT images were calculated. Results: The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V-20Gy of lung were -0.3% +/- 0.4% and -0.7% +/- 2.4%, 1.6 +/- 27.9 cGy, -1.6 +/- 37.6cGy, 15.9 +/- 25.3cGy and 0.0%+/- 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. Conclusion: In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Advances in knowledge: Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Stereotactic ablative radiotherapy utilising volumetric modulated arc therapy
    Harrow, S.
    LUNG CANCER, 2013, 79 : S62 - S62
  • [2] Dosimetric impact of rotational setup errors in volumetric modulated arc therapy for postoperative cervical cancer
    Tsujii, Katsutomo
    Ueda, Yoshihiro
    Isono, Masaru
    Miyazaki, Masayoshi
    Teshima, Teruki
    Koizumi, Masahiko
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (04) : 688 - 698
  • [3] Dosimetric effects of rotational setup error in volumetric modulated arc radiotherapy on brain tumor patients
    Park H.-K.
    Cho J.-H.
    Kim S.
    Iranian Journal of Medical Physics, 2019, 16 (02) : 171 - 178
  • [4] Dosimetric Impact of Rotational Setup Errors for Cervical Cancer Patients With Postoperative Volumetric Modulated Arc Therapy
    Tsujii, K.
    Ueda, Y.
    Isono, M.
    Miyazaki, M.
    Teshima, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E603 - E603
  • [5] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [6] Volumetric Modulated Arc Therapy for Delivery of Stereotactic Lung Radiotherapy: A Dosimetric and Treatment Efficiency Analysis
    McGrath, S. D.
    Matuszak, M.
    Yan, D.
    Kestin, L.
    Martinez, A.
    Grills, I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S683 - S683
  • [7] A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy
    Thanh, Nguyen Van
    Tuong, Pham Nguyen
    Tai, Duong Thanh
    Loan, Truong Thi Hong
    Sandwall, Peter
    Bradley, David
    Chow, James C. L.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (04)
  • [8] Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc Therapy
    Rao, Min
    Wu, Jianzhou
    Cao, Daliang
    Wong, Tony
    Mehta, Vivek
    Shepard, David
    Ye, Jinsong
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : E251 - E256
  • [9] Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis
    McGrath, Samuel D.
    Matuszak, Martha M.
    Yan, Di
    Kestin, Larry L.
    Martinez, Alvaro A.
    Grills, Inga S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 153 - 157
  • [10] Dosimetric Impact of Rotational Setup Errors on Multiple Brain Targets Treated with Single Isocenter Volumetric Modulated Arc Therapy
    Xue, J.
    No, D.
    Zhang, J.
    Wang, H.
    Barbee, D.
    Lymberis, S.
    Silverman, J.
    Das, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E615 - E615