Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy

被引:11
|
作者
Lee, Jaegi [1 ,2 ]
Kim, Jung-In [2 ,3 ,4 ,5 ]
Ye, Sung-Joon [1 ,3 ]
Kim, Hak Jae [3 ,4 ,6 ]
Carlson, Joel [1 ,2 ]
Park, Jong Min [2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Biomed Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[5] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
[6] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1055期
关键词
BODY RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONE-BEAM CT; CANCER; METASTASES; GUIDANCE; POSITION; PATIENT;
D O I
10.1259/bjr.20140862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). Methods: A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by +/- 1 degrees, +/- 2 degrees and +/- 3 degrees. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D-95% and V-100% of the target volume, D-0.35cc of spinal cord, D-0.35cc and D-5cc of oesophagus and V-20Gy of lung between the original and the rotated CT images were calculated. Results: The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V-20Gy of lung were -0.3% +/- 0.4% and -0.7% +/- 2.4%, 1.6 +/- 27.9 cGy, -1.6 +/- 37.6cGy, 15.9 +/- 25.3cGy and 0.0%+/- 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. Conclusion: In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Advances in knowledge: Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Developing a class solution for Prostate Stereotactic Ablative Body Radiotherapy (SABR) using Volumetric Modulated Arc Therapy (VMAT)
    Murray, Louise J.
    Cosgrove, Vivian
    Lilley, John
    Sykes, Jonathan
    Thompson, Christopher M.
    Franks, Kevin
    Sebag-Montefiore, David
    Henry, Ann M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (02) : 298 - 302
  • [22] Stereotactic Body Radiotherapy (SBRT) Treatment of Lung Lesions using Volumetric Modulated Arc Therapy (VMAT)
    Le, Y.
    Song, D.
    Ford, E.
    Kang, J.
    Wong, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S797 - S797
  • [23] Motion Analysis of Target during Stereotactic Radiotherapy of Lung Tumors Using Volumetric Modulated Arc Therapy
    Imae, T.
    Haga, A.
    Onoe, T.
    Nakagawa, K.
    Ino, K.
    Okano, Y.
    Tanaka, K.
    Sasaki, K.
    Saegusa, S.
    Shiraki, T.
    Oritate, T.
    Yano, K.
    Shinohara, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] Dosimetric effect of rotational setup errors in volumetric modulated arc therapy and field-in-field treatment of left-sided breast cancer
    Heikkilae, Annele
    Boman, Eeva
    Rossi, Maija
    Vanhanen, Antti
    Mankinen, Mikko
    Postema, Michiel
    Koivumaeki, Tuomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 117
  • [25] Comparative dosimetric analysis of intensity modulated radiotherapy and volumetric modulated arc therapy
    Ali, M. Athar
    Babaiah, M.
    George, G.
    Madhusudhan, N.
    Ramalingam, K.
    Kumar, S. Ashok
    Karthikeyan, K.
    Anantharaman, A.
    Shanu, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S188 - S188
  • [26] Chest wall dose reduction using noncoplanar volumetric modulated arc radiation therapy for lung stereotactic ablative radiation therapy
    Yu, Amy S.
    Maxim, Peter G.
    Loo, Billy W., Jr.
    Gensheimer, Michael F.
    PRACTICAL RADIATION ONCOLOGY, 2018, 8 (04) : E199 - E207
  • [27] Two-arc volumetric modulated arc therapy to provide dosimetric advantages for pancreas stereotactic body radiotherapy.
    Molitoris, Jason K.
    Brown, Christopher
    Chen, Shifeng
    Marter, Kimberly
    Spaeth, Kristin
    Regine, William
    Chuong, Michael David
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (04)
  • [28] Hypofractionated Stereotactic Radiotherapy for Brain Metastases: A Dosimetric and Treatment Efficiency Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy
    Ma, Y.
    Yu, J.
    Li, M.
    Yin, Y.
    Kong, L.
    Sun, X.
    Lin, X.
    Yang, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S837 - S837
  • [29] Hypofractionated Stereotactic Radiotherapy for Brain Metastases: A Dosimetric and Treatment Efficiency Comparison Between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy
    Ma, Yidong
    Li, Minghuan
    Yin, Yong
    Kong, Li
    Sun, Xindong
    Lin, Xiutong
    Yu, Jinming
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) : 499 - 507
  • [30] Prostate Stereotactic Ablative Radiation Therapy Using Volumetric Modulated Arc Therapy to Dominant Intraprostatic Lesions
    Murray, Louise J.
    Lilley, John
    Thompson, Christopher M.
    Cosgrove, Vivian
    Mason, Josh
    Sykes, Jonathan
    Franks, Kevin
    Sebag-Montefiore, David
    Henry, Ann M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (02): : 406 - 415