Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy

被引:11
|
作者
Lee, Jaegi [1 ,2 ]
Kim, Jung-In [2 ,3 ,4 ,5 ]
Ye, Sung-Joon [1 ,3 ]
Kim, Hak Jae [3 ,4 ,6 ]
Carlson, Joel [1 ,2 ]
Park, Jong Min [2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Biomed Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[5] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
[6] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1055期
关键词
BODY RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONE-BEAM CT; CANCER; METASTASES; GUIDANCE; POSITION; PATIENT;
D O I
10.1259/bjr.20140862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). Methods: A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by +/- 1 degrees, +/- 2 degrees and +/- 3 degrees. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D-95% and V-100% of the target volume, D-0.35cc of spinal cord, D-0.35cc and D-5cc of oesophagus and V-20Gy of lung between the original and the rotated CT images were calculated. Results: The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V-20Gy of lung were -0.3% +/- 0.4% and -0.7% +/- 2.4%, 1.6 +/- 27.9 cGy, -1.6 +/- 37.6cGy, 15.9 +/- 25.3cGy and 0.0%+/- 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. Conclusion: In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Advances in knowledge: Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] The effect of arm position on the dosimetry of thoracic stereotactic ablative radiation therapy using volumetric modulated arc therapy
    Shultz, David B.
    Jang, Seong Sun
    Hanlon, Alexandra L.
    Diehn, Maximilian
    Loo, Billy W., Jr.
    Maxim, Peter G.
    PRACTICAL RADIATION ONCOLOGY, 2014, 4 (03) : 192 - 197
  • [42] Evaluation of Spine Stereotactic Body Radiotherapy (SBRT) Using Volumetric Modulated Arc Therapy (Rapid Arc)
    Sharma, P. K.
    Srivastava, R.
    Noufal, M.
    Garg, M.
    Nangia, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S875 - S875
  • [43] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [44] Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Law, Gilbert M. L.
    Tam, Eric
    Tong, Anthony
    Lee, Venus
    Ng, Sherry C. Y.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 136 - 149
  • [45] Dosimetric Comparison of Volumetric Arc Therapy and Intensity Modulated Radiotherapy for Glioblastoma Treatment
    Kaptan, I.
    Ugurluer, G.
    Ispir, B.
    Akdeniz, Y.
    Serin, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [46] Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma
    Paik, Eun Kyung
    Kim, Mi-Sook
    Choi, Chul Won
    Il Jang, Won
    Lee, Sung Hyun
    Choi, Sang Hyoun
    Kim, Kum Bae
    Lee, Dong Han
    RADIATION ONCOLOGY JOURNAL, 2015, 33 (03): : 233 - 241
  • [47] Dosimetric impact of breathing motion in lung stereotactic body radiotherapy treatment using image-modulated radiotherapy and volumetric modulated arc therapy (vol 83, pg e251, 2012)
    Rao, M.
    Wu, J.
    Cao, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (02): : 462 - 462
  • [48] Dosimetric Consequences of Rotational Setup Errors Using Direct Simulation in a Treatment Planning System for Fractionated Stereotactic Radiotherapy (SRT)
    Peng, J.
    Chen, Y.
    Liu, C.
    Kahler, D.
    Li, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [49] ROLE OF VOLUMETRIC MODULATED ARC THERAPY WITH FLATTENING FILTER FREE DELIVERY IN LUNG STEREOTACTIC BODY RADIOTHERAPY
    Liu, Hongwei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S68 - S68
  • [50] A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy
    Rauschenbach, Bradley M.
    Mackowiak, Luke
    Malhotra, Harish K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 147 - 161