A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy

被引:0
|
作者
Thanh, Nguyen Van [1 ]
Tuong, Pham Nguyen [1 ]
Tai, Duong Thanh [2 ]
Loan, Truong Thi Hong [3 ,4 ,5 ]
Sandwall, Peter [6 ]
Bradley, David [7 ,8 ]
Chow, James C. L. [9 ,10 ]
机构
[1] Hue Cent Hosp, Oncol Ctr, Le Loi St, Hue City, Thua Thien Hue, Vietnam
[2] Nguyen Tat Thanh Univ, Fac Med, Dept Med Phys, 298-300A Nguyen Tat Thanh St,Ward 13,Dist 4, Ho Chi Minh City, Vietnam
[3] Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
[4] Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City, Vietnam
[5] Vietnam Natl Univ, Ho Chi Minh City, Vietnam
[6] OhioHealth, Mansfield Hosp, Dept Radiat Oncol, Mansfield, OH USA
[7] Sunway Univ, Appl Phys & Radiat Technol Grp, CCDCU, Pj 46150, Malaysia
[8] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[9] Univ Toronto, Dept Radiat Oncol, Toronto, ON N5T 1P5, Canada
[10] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
关键词
Lung stereotactic body radiotherapy (SBRT); Dynamic conformal arc therapy (DCAT); Volumetric modulated arc therapy (VMAT); Quality assurance (QA); RADIATION-THERAPY; QUALITY-ASSURANCE; PLANS;
D O I
10.1016/j.net.2024.11.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose: This study assesses the viability of utilizing dynamic conformal arc therapy (DCAT) as an alternative to volumetric-modulated arc therapy (VMAT) in stereotactic body radiation therapy (SBRT) for lung cancer, with a focus on four-dimensional computed tomography (4DCT) in free-breathing conditions. Materials and methods: We selected four non-small cell lung cancer (NSCLC) patients who had previously undergone VMAT SBRT and re-planned their treatment using DCAT. We compared the DCAT and VMAT plans based on dose distribution, conformity index (CI), homogeneity index (HI), gradient index (GI), and total monitor units (MUs). Quality assurance (QA) assessments for both plans were conducted using the Octavius 4D system (PTW, Freiburg, Germany). Results: The results showed that CIPaddick was 0.80 f 0.06 and 0.79 f 0.04 (p-value >0.05), HI was 1.16 f 0.03 (p-value <0.05) and 1.07 f 0.02, GI was 3.91 f 0.05 and 3.40 f 0.05 (p-value <0.05), and MU was 1880.42 f 135.19 and 5020.82 f 188.03 for DCAT and VMAT, respectively (p-value <0.05). The average gamma passing rate exceeded 95 % with a 2 %/2 mm criteria. The dose distribution displayed remarkable similarity between DCAT and VMAT. Conclusion: The DCAT technique exhibits the capacity to deliver PTV dose distributions comparable to those achieved with VMAT, while significantly reducing treatment duration.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [2] Dosimetric and radiobiological evaluation of stereotactic radiosurgery using volumetric modulated arc therapy and dynamic conformal arc therapy for multiple brain metastases
    Jiang, Chen-Jun
    Ho, Yick-Wing
    Lok, Ka-Hei
    Lu, Yeow-Yuen
    Zhu, Chun-Ran
    Cheng, Harry Chi-Yuen
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [3] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yucel
    JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (01): : 19 - 24
  • [4] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yuecel
    ERCIYES MEDICAL JOURNAL, 2023, 45 (01) : 19 - 24
  • [5] A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy
    Rauschenbach, Bradley M.
    Mackowiak, Luke
    Malhotra, Harish K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 147 - 161
  • [6] Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy
    Bokrantz, Rasmus
    Wedenberg, Minna
    Sandwall, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 103 - 109
  • [7] Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy
    Vieillevigne, Laure
    Bessieres, Sandra
    Ouali, Monia
    Lanaspeze, Christel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1405 - 1414
  • [8] Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer
    Ming, Xin
    Feng, Yuanming
    Liu, Huan
    Zhang, Ying
    Zhou, Li
    Deng, Jun
    PLOS ONE, 2015, 10 (12):
  • [9] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [10] Dosimetric comparison: volumetric modulated arc therapy and stereotactic body radiotherapy for prostate cancer patients
    Cheung, E. Y. W.
    Chan, G. C. K.
    Ma, R. W. S.
    Nip, E. Y.
    Fong, K.
    Wong, J. S. Y.
    Lam, C. N. K.
    ANNALS OF ONCOLOGY, 2024, 35 : S1328 - S1329