A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy

被引:0
|
作者
Thanh, Nguyen Van [1 ]
Tuong, Pham Nguyen [1 ]
Tai, Duong Thanh [2 ]
Loan, Truong Thi Hong [3 ,4 ,5 ]
Sandwall, Peter [6 ]
Bradley, David [7 ,8 ]
Chow, James C. L. [9 ,10 ]
机构
[1] Hue Cent Hosp, Oncol Ctr, Le Loi St, Hue City, Thua Thien Hue, Vietnam
[2] Nguyen Tat Thanh Univ, Fac Med, Dept Med Phys, 298-300A Nguyen Tat Thanh St,Ward 13,Dist 4, Ho Chi Minh City, Vietnam
[3] Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
[4] Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City, Vietnam
[5] Vietnam Natl Univ, Ho Chi Minh City, Vietnam
[6] OhioHealth, Mansfield Hosp, Dept Radiat Oncol, Mansfield, OH USA
[7] Sunway Univ, Appl Phys & Radiat Technol Grp, CCDCU, Pj 46150, Malaysia
[8] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[9] Univ Toronto, Dept Radiat Oncol, Toronto, ON N5T 1P5, Canada
[10] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
关键词
Lung stereotactic body radiotherapy (SBRT); Dynamic conformal arc therapy (DCAT); Volumetric modulated arc therapy (VMAT); Quality assurance (QA); RADIATION-THERAPY; QUALITY-ASSURANCE; PLANS;
D O I
10.1016/j.net.2024.11.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose: This study assesses the viability of utilizing dynamic conformal arc therapy (DCAT) as an alternative to volumetric-modulated arc therapy (VMAT) in stereotactic body radiation therapy (SBRT) for lung cancer, with a focus on four-dimensional computed tomography (4DCT) in free-breathing conditions. Materials and methods: We selected four non-small cell lung cancer (NSCLC) patients who had previously undergone VMAT SBRT and re-planned their treatment using DCAT. We compared the DCAT and VMAT plans based on dose distribution, conformity index (CI), homogeneity index (HI), gradient index (GI), and total monitor units (MUs). Quality assurance (QA) assessments for both plans were conducted using the Octavius 4D system (PTW, Freiburg, Germany). Results: The results showed that CIPaddick was 0.80 f 0.06 and 0.79 f 0.04 (p-value >0.05), HI was 1.16 f 0.03 (p-value <0.05) and 1.07 f 0.02, GI was 3.91 f 0.05 and 3.40 f 0.05 (p-value <0.05), and MU was 1880.42 f 135.19 and 5020.82 f 188.03 for DCAT and VMAT, respectively (p-value <0.05). The average gamma passing rate exceeded 95 % with a 2 %/2 mm criteria. The dose distribution displayed remarkable similarity between DCAT and VMAT. Conclusion: The DCAT technique exhibits the capacity to deliver PTV dose distributions comparable to those achieved with VMAT, while significantly reducing treatment duration.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A Planning Comparison of 3D Conformal Multiple Static Field, Conformal Arc, and Volumetric Modulated Arc Therapy for the Delivery of Stereotactic Body Radiation Therapy for Lung Cancer
    Gabos, Z.
    Dickey, M. J.
    Drodge, S.
    Murray, B.
    Ghosh, S.
    Scrimger, R.
    Roa, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S901 - S901
  • [42] Dosimetric evaluation of respiratory gated volumetric modulated arc therapy for lung stereotactic body radiation therapy using 3D printing technology
    Yoon, KyoungJun
    Jeong, Chiyoung
    Kim, Sung-woo
    Cho, Byungchul
    Kwak, Jungwon
    Kim, Su Ssan
    Song, Si Yeol
    Choi, Eun Kyung
    Ahn, SeungDo
    Lee, Sang-Wook
    PLOS ONE, 2018, 13 (12):
  • [43] Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Law, Gilbert M. L.
    Tam, Eric
    Tong, Anthony
    Lee, Venus
    Ng, Sherry C. Y.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 136 - 149
  • [44] A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer
    Dickey, Mike
    Roa, Wilson
    Drodge, Suzanne
    Ghosh, Sunita
    Murray, Brad
    Scrimger, Rufus
    Gabos, Zsolt
    MEDICAL DOSIMETRY, 2015, 40 (04) : 347 - 351
  • [45] Dosimetric Evaluation of Proton Arc Therapy for Brain Stereotactic Radiotherapy
    Min, B.
    Kim, D.
    Yoo, S.
    Jeong, H.
    Lee, S.
    Shin, D.
    Lee, S.
    Park, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3634 - +
  • [46] Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy
    Liu, Hong-Wei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (02) : 155 - 159
  • [47] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [48] Fractionated stereotactic radiotherapy with volumetric modulated arc therapy for pituitary adenoma
    Castano Cantos, A.
    Rodriguez Roldan, M.
    Gonzalez del Portillo, E.
    Garrido Botella, I.
    Teja Ubach, M.
    Gonzalez Cantero, M.
    Rosel Aller, R.
    Deben Mendez, B.
    Matute Martin, R.
    Morera Lopez, R.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S898 - S899
  • [49] Evaluation of Hybrid Arc and Volumetric-Modulated Arc Therapy Treatment Plans for Fractionated Stereotactic Intracranial Radiotherapy
    Li, Jun
    To, David
    Gunn, Vickie
    Shi, Wenyin
    Yu, Yan
    Liu, Haisong
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17 : 1 - 6
  • [50] A dosimetric study of dynamic conformal arc therapy for lung cancer
    Cho, N. K.
    Maxim, P. G.
    Loo, B. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S687 - S687