Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume

被引:0
|
作者
Saglam, Yuecel [1 ,2 ]
机构
[1] Amer Hosp, MD Anderson Radiat Treatment Ctr, Istanbul, Turkiye
[2] Koc Univ, Fac Med, Dept Radiat Oncol, Istanbul, Turkiye
关键词
Dynamic conformal arc; lung cancer; stereotactic body radiotherapy; treatment technique; volumetric modulated arc therapy; RADIATION-THERAPY; MOTION; MANAGEMENT; IMRT; SBRT; DELIVERY;
D O I
10.14744/etd.2022.96572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This retrospective study constitutes a feasibility assessment of dynamic conformal arc (DCA) therapy as an alter-native to volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer (LC) with the free breathing technique using internal target volume. DCA is to create a more efficient treatment reducing beam-on time (BOT) and monitor unit (MU) without interplay errors except for complex tumor geometries when compared to volumetric modulated arc therapy (VMAT).Materials and Methods: CT images and plans of forty patients treated with 50 Gy prescription in four fractions using VMAT technique for SBRT treatment of LC selected. Plans were re-planned with using DCA technique. VMAT and DCA plans compared via The Radiation Therapy Oncology Group (RTOG) Protocol 0915 for conformity and efficient having pass rate of gamma index in quality assurance (QA), MU and BOT.Results: The study included 40 patients. The mean value of QA pass rate 99.10 +/- 1.49 in DCA and 92.34 +/- 1.96 in VMAT. The rate was higher in DCA (p<0.001 and t=8.98). The values of BOT and MU were 4.68 min and 3296 in the VMAT tech-nique and they were 3.58 min and 2395 in DCA. These values were significantly improved with DCA (p<0.001 and p<0.001).Conclusion: DCA can potentially minimize multi-leaf collimator errors from respiratory motion and small-field dosimetry. It delivery similar doses of treatment quality to tumor while providing faster treatment by significantly reducing MU and BOT compared to VMAT and moreover offers same-day SBRT treatments without the need for specific QA.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [1] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yucel
    JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (01): : 19 - 24
  • [2] A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy
    Thanh, Nguyen Van
    Tuong, Pham Nguyen
    Tai, Duong Thanh
    Loan, Truong Thi Hong
    Sandwall, Peter
    Bradley, David
    Chow, James C. L.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (04)
  • [3] A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy
    Rauschenbach, Bradley M.
    Mackowiak, Luke
    Malhotra, Harish K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 147 - 161
  • [4] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [5] Dosimetric comparison: volumetric modulated arc therapy and stereotactic body radiotherapy for prostate cancer patients
    Cheung, E. Y. W.
    Chan, G. C. K.
    Ma, R. W. S.
    Nip, E. Y.
    Fong, K.
    Wong, J. S. Y.
    Lam, C. N. K.
    ANNALS OF ONCOLOGY, 2024, 35 : S1328 - S1329
  • [6] Volumetric Modulated Arc Therapy for Delivery of Stereotactic Lung Radiotherapy: A Dosimetric and Treatment Efficiency Analysis
    McGrath, S. D.
    Matuszak, M.
    Yan, D.
    Kestin, L.
    Martinez, A.
    Grills, I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S683 - S683
  • [7] Planning Comparison of Volumetric Modulated Arc Therapy and Dynamic Conformal Arc for Intracranial Fractionated Stereotactic Radiotherapy Using BrainLAB Cranial SRS and IPlan
    Geraghty, C.
    Carroll, J.
    Li, T.
    Hasson, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E417 - E417
  • [8] Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy
    Bokrantz, Rasmus
    Wedenberg, Minna
    Sandwall, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 103 - 109
  • [9] A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer
    Dickey, Mike
    Roa, Wilson
    Drodge, Suzanne
    Ghosh, Sunita
    Murray, Brad
    Scrimger, Rufus
    Gabos, Zsolt
    MEDICAL DOSIMETRY, 2015, 40 (04) : 347 - 351
  • [10] Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery
    Molinier, Jessica
    Kerr, Christine
    Simeon, Sebastien
    Ailleres, Norbert
    Charissoux, Marie
    Azria, David
    Fenoglietto, Pascal
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 92 - 101