Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume

被引:0
|
作者
Saglam, Yuecel [1 ,2 ]
机构
[1] Amer Hosp, MD Anderson Radiat Treatment Ctr, Istanbul, Turkiye
[2] Koc Univ, Fac Med, Dept Radiat Oncol, Istanbul, Turkiye
关键词
Dynamic conformal arc; lung cancer; stereotactic body radiotherapy; treatment technique; volumetric modulated arc therapy; RADIATION-THERAPY; MOTION; MANAGEMENT; IMRT; SBRT; DELIVERY;
D O I
10.14744/etd.2022.96572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This retrospective study constitutes a feasibility assessment of dynamic conformal arc (DCA) therapy as an alter-native to volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer (LC) with the free breathing technique using internal target volume. DCA is to create a more efficient treatment reducing beam-on time (BOT) and monitor unit (MU) without interplay errors except for complex tumor geometries when compared to volumetric modulated arc therapy (VMAT).Materials and Methods: CT images and plans of forty patients treated with 50 Gy prescription in four fractions using VMAT technique for SBRT treatment of LC selected. Plans were re-planned with using DCA technique. VMAT and DCA plans compared via The Radiation Therapy Oncology Group (RTOG) Protocol 0915 for conformity and efficient having pass rate of gamma index in quality assurance (QA), MU and BOT.Results: The study included 40 patients. The mean value of QA pass rate 99.10 +/- 1.49 in DCA and 92.34 +/- 1.96 in VMAT. The rate was higher in DCA (p<0.001 and t=8.98). The values of BOT and MU were 4.68 min and 3296 in the VMAT tech-nique and they were 3.58 min and 2395 in DCA. These values were significantly improved with DCA (p<0.001 and p<0.001).Conclusion: DCA can potentially minimize multi-leaf collimator errors from respiratory motion and small-field dosimetry. It delivery similar doses of treatment quality to tumor while providing faster treatment by significantly reducing MU and BOT compared to VMAT and moreover offers same-day SBRT treatments without the need for specific QA.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [31] Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
    Oechsner, Markus
    Odersky, Leonhard
    Berndt, Johannes
    Combs, Stephanie Elisabeth
    Wilkens, Jan Jakob
    Duma, Marciana Nona
    RADIATION ONCOLOGY, 2015, 10
  • [32] Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
    Mallory, Matthew
    Pokhrel, Damodar
    Badkul, Rajeev
    Jiang, Hongyu
    Lominska, Christopher
    Wang, Fen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 54 - 61
  • [33] Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
    Markus Oechsner
    Leonhard Odersky
    Johannes Berndt
    Stephanie Elisabeth Combs
    Jan Jakob Wilkens
    Marciana Nona Duma
    Radiation Oncology, 10
  • [34] Motion Analysis of Target during Stereotactic Radiotherapy of Lung Tumors Using Volumetric Modulated Arc Therapy
    Imae, T.
    Haga, A.
    Onoe, T.
    Nakagawa, K.
    Ino, K.
    Okano, Y.
    Tanaka, K.
    Sasaki, K.
    Saegusa, S.
    Shiraki, T.
    Oritate, T.
    Yano, K.
    Shinohara, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [35] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Fujimoto, Daimu
    Takatsu, Jun
    Hara, Naoya
    Oshima, Masaki
    Tomihara, Jun
    Segawa, Eisuke
    Inoue, Tatsuya
    Shikama, Naoto
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 143 - 152
  • [36] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Daimu Fujimoto
    Jun Takatsu
    Naoya Hara
    Masaki Oshima
    Jun Tomihara
    Eisuke Segawa
    Tatsuya Inoue
    Naoto Shikama
    Radiological Physics and Technology, 2024, 17 : 143 - 152
  • [37] Is IMAT the ultimate evolution of conformal radiotherapy? Dosimetric comparison of helical tomotherapy and volumetric modulated arc therapy for oropharyngeal cancer in a planning study
    Vernat, Stephanie Servagi
    Ali, David
    Puyraveau, Marc
    Viard, Romain
    Lisbona, Albert
    Fenoglietto, Pascal
    Bedos, Ludovic
    Makovicka, Libor
    Giraud, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 280 - 285
  • [38] Evaluation of Spine Stereotactic Body Radiotherapy (SBRT) Using Volumetric Modulated Arc Therapy (Rapid Arc)
    Sharma, P. K.
    Srivastava, R.
    Noufal, M.
    Garg, M.
    Nangia, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S875 - S875
  • [39] Comparison of Conformal and Volumetric Modulated Arc Techniques According to RTOG 0915 Protocol Treatment Planning Guidelines in Stereotactic Lung Radiation Therapy
    Baslangic, B.
    Gungor, G.
    Atalar, B.
    Uluer, M.
    Karademir, M.
    Aydin, G.
    Sahin, B.
    Yapici, B.
    Ozyar, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E553 - E554
  • [40] Stereotactic Body Radiotherapy (SBRT) Treatment of Lung Lesions using Volumetric Modulated Arc Therapy (VMAT)
    Le, Y.
    Song, D.
    Ford, E.
    Kang, J.
    Wong, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S797 - S797