Left Atrial Appendage Closure: A Single Center Experience and Comparison of Two Contemporary Devices

被引:28
|
作者
Figini, Filippo [1 ,2 ]
Mazzone, Patrizio [1 ]
Regazzoli, Damiano [1 ]
Porata, Giulia [1 ]
Ruparelia, Neil [1 ,2 ,3 ]
Giannini, Francesco [1 ,2 ]
Stella, Stefano [1 ]
Ancona, Francesco [1 ]
Agricola, Eustachio [1 ]
Sora, Nicoleta [1 ]
Marzi, Alessandra [1 ]
Aurelio, Andrea [1 ]
Trevisi, Nicola [1 ]
Della Bella, Paolo [1 ]
Colombo, Antonio [1 ,2 ]
Montorfano, Matteo [1 ]
机构
[1] Hosp San Raffaele, Intervent Cardiol Dept, Milan, Italy
[2] EMO GVM Ctr Cuore Columbus, Milan, Italy
[3] Imperial Coll, London, England
关键词
atrial fibrillation; stroke; antithrombotic agents; WATCHMAN DEVICE; RISK-FACTORS; WARFARIN USE; FIBRILLATION; STROKE; ANTICOAGULATION; VALIDATION; PREVENTION; OCCLUSION; REDUCE;
D O I
10.1002/ccd.26678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. Background: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. Methods: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. Results: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 626 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks >= 1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. Conclusions: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:763 / 772
页数:10
相关论文
共 50 条
  • [41] Left atrial appendage closure devices: A reasonable therapeutic alternative
    Reddy, Vivek Y.
    HEART RHYTHM, 2018, 15 (02) : 302 - 305
  • [42] Exploring the dark side of left atrial appendage closure devices
    Santangeli, Pasquale
    Epstein, Andrew E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (01) : 14 - 16
  • [43] Left atrial appendage closure devices. Their role in 2013
    Mangner, N.
    Sandri, M.
    Lurz, P.
    Daehnert, I.
    Schuler, G.
    Moebius-Winkler, S.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (02): : 125 - 134
  • [44] SAFETY, FEASIBILITY AND ECONOMIC IMPACT OF SAME DAY DISCHARGE AFTER LEFT ATRIAL APPENDAGE CLOSURE - SINGLE CENTER EXPERIENCE
    Yaganti, Vamsee
    Nalabothu, Poorna
    Allred, Laycie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1093 - 1093
  • [45] Delayed Pericardial Effusion Following Left Atrial Appendage Closure: A 5-Year Single-Center Experience
    Kumar, Sundeep
    Lobo, Tabitha
    Reed, Joseph
    Dallan, Luis Augusto Palma
    Yoon, Sung-Han
    Filby, Steven
    Mogalapalli, Akhil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B159 - B160
  • [46] Delayed Pericardial Effusion Following Left Atrial Appendage Closure: A 5-Year Single-Center Experience
    Mogalapalli, Akhil
    Kumar, Sundeep
    Lobo, Tabitha
    Reed, Joseph
    Dallan, Luis Augusto Palma
    Yoon, Sung-Han
    Filby, Steven J.
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (01): : E1 - E6
  • [47] Percutaneous left atrial appendage closure (LAA) with the new generation watchman device single center experience in 48 patients
    Lehn, K.
    Wunderlich, N.
    Sievert, H.
    EUROPEAN HEART JOURNAL, 2009, 30 : 599 - 599
  • [48] Left atrial appendage closure
    Singh I.M.
    Holmes Jr. D.R.
    Current Cardiology Reports, 2010, 12 (5) : 413 - 421
  • [49] Left Atrial Appendage Closure
    Lin, Albert C.
    Knight, Bradley P.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 58 (02) : 195 - 201
  • [50] LEFT ATRIAL APPENDAGE CLOSURE
    Bertog, S.
    Vaskelyte, L.
    Hofmann, I.
    Lam, S.
    Gafoor, S.
    Wiebe, J.
    Sievert, H.
    CARDIOLOGY, 2013, 125 : 247 - 247