Left Atrial Appendage Closure: A Single Center Experience and Comparison of Two Contemporary Devices

被引:28
|
作者
Figini, Filippo [1 ,2 ]
Mazzone, Patrizio [1 ]
Regazzoli, Damiano [1 ]
Porata, Giulia [1 ]
Ruparelia, Neil [1 ,2 ,3 ]
Giannini, Francesco [1 ,2 ]
Stella, Stefano [1 ]
Ancona, Francesco [1 ]
Agricola, Eustachio [1 ]
Sora, Nicoleta [1 ]
Marzi, Alessandra [1 ]
Aurelio, Andrea [1 ]
Trevisi, Nicola [1 ]
Della Bella, Paolo [1 ]
Colombo, Antonio [1 ,2 ]
Montorfano, Matteo [1 ]
机构
[1] Hosp San Raffaele, Intervent Cardiol Dept, Milan, Italy
[2] EMO GVM Ctr Cuore Columbus, Milan, Italy
[3] Imperial Coll, London, England
关键词
atrial fibrillation; stroke; antithrombotic agents; WATCHMAN DEVICE; RISK-FACTORS; WARFARIN USE; FIBRILLATION; STROKE; ANTICOAGULATION; VALIDATION; PREVENTION; OCCLUSION; REDUCE;
D O I
10.1002/ccd.26678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. Background: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. Methods: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. Results: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 626 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks >= 1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. Conclusions: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:763 / 772
页数:10
相关论文
共 50 条
  • [31] Primary and Secondary Stroke Prevention Using Left Atrial Appendage Closure with Watchman Devices in Atrial Fibrillation Patients: A Single Center Experience from Mainland China
    Chen, Yanhong
    Zhang, Yonghua
    Huang, Weiping
    Huang, Keqiang
    Xu, Bei
    Su, Xi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (06): : 607 - 614
  • [32] Left atrial appendage closure: Single-center experience with the 4th generation Watchman device
    Gonzaga, Maik
    Bertog, Stefan C.
    Braut, Annkathrin
    Bauer, Janine
    Boehm, Patrick
    Hofmann, Ilona
    Vaskelyte, Laura
    Sievert, Horst
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B211 - B212
  • [33] Left atrial appendage closure followed by 6 weeks of antithrombotic therapy: A prospective single-center experience
    Chun, K. R. Julian
    Bordignon, Stefano
    Urban, Verena
    Perrotta, Laura
    Dugo, Daniela
    Fuernkranz, Alexander
    Nowak, Bernd
    Schmidt, Boris
    HEART RHYTHM, 2013, 10 (12) : 1792 - 1799
  • [34] Left atrial appendage closure as an alternative to oral antikoaguation in high risk patients: a single-center experience
    Mihaila, R.
    Reiner, C.
    Humaid, B.
    Schaefer, M.
    Gabrecht, M.
    Stefan, S.
    Jacksch, R.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1109 - 1110
  • [35] Periprocedural Intracardiac Echocardiography for Left Atrial Appendage Closure A Dual-Center Experience
    Berti, Sergio
    Paradossi, Umberto
    Meucci, Francesco
    Trianni, Giuseppe
    Tzikas, Apostolos
    Rezzaghi, Marco
    Stolkova, Miroslava
    Palmieri, Cataldo
    Mori, Fabio
    Santoro, Gennaro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (09) : 1036 - 1044
  • [36] Canadian Multi-Center Experience with WATCHMAN for Percutaneous Left Atrial Appendage Closure
    Saw, Jacqueline
    Fahmy, Peter
    Azzalini, Lorenzo
    Marquis, Jean-Francois
    Hibbert, Benjamin
    Morillo, Carlos
    Carrizo, Aldo
    Ibrahim, Reda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B296 - B297
  • [37] Canadian Multi-center Experience With WATCHMAN for Percutaneous Left Atrial Appendage Closure
    Saw, Jacqueline
    Fahmy, Peter
    Azzalini, Lorenzo
    Marquis, Jean-Francois
    Hibbert, Benjamin
    Morillo, Carlos
    Carrizo, Aldo
    Ibrahim, Reda
    CIRCULATION, 2015, 132
  • [38] Imaging for Percutaneous Left Atrial Appendage Closure: A Contemporary Review
    Ramchand, Jay
    Harb, Serge C.
    Miyasaka, Rhonda
    Kanj, Mohamed
    Saliba, Walid
    Jaber, Wael A.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (05): : 364 - 382
  • [39] Transcatheter left atrial appendage occlusion: a 10-year single center experience using Amplatzer devices
    Shakir, S.
    Gloekler, S.
    Khattab, A.
    Wenaweser, P.
    Windecker, S.
    Nietlispach, F.
    Meier, B.
    EUROPEAN HEART JOURNAL, 2013, 34 : 652 - 653
  • [40] Closure of Left Atrial Appendage to Prevent Stroke: Devices and Status
    Safavi-Naeini, Payam
    Rasekh, Abdi
    TEXAS HEART INSTITUTE JOURNAL, 2018, 45 (03): : 172 - 174