Left Atrial Appendage Closure: A Single Center Experience and Comparison of Two Contemporary Devices

被引:28
|
作者
Figini, Filippo [1 ,2 ]
Mazzone, Patrizio [1 ]
Regazzoli, Damiano [1 ]
Porata, Giulia [1 ]
Ruparelia, Neil [1 ,2 ,3 ]
Giannini, Francesco [1 ,2 ]
Stella, Stefano [1 ]
Ancona, Francesco [1 ]
Agricola, Eustachio [1 ]
Sora, Nicoleta [1 ]
Marzi, Alessandra [1 ]
Aurelio, Andrea [1 ]
Trevisi, Nicola [1 ]
Della Bella, Paolo [1 ]
Colombo, Antonio [1 ,2 ]
Montorfano, Matteo [1 ]
机构
[1] Hosp San Raffaele, Intervent Cardiol Dept, Milan, Italy
[2] EMO GVM Ctr Cuore Columbus, Milan, Italy
[3] Imperial Coll, London, England
关键词
atrial fibrillation; stroke; antithrombotic agents; WATCHMAN DEVICE; RISK-FACTORS; WARFARIN USE; FIBRILLATION; STROKE; ANTICOAGULATION; VALIDATION; PREVENTION; OCCLUSION; REDUCE;
D O I
10.1002/ccd.26678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. Background: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. Methods: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. Results: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 626 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks >= 1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. Conclusions: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:763 / 772
页数:10
相关论文
共 50 条
  • [21] Percutaneous left atrial appendage closure in patients with non-valvular atrial fibrillation: a single center experience
    Li Huakang
    Yao Qing
    Shu Maoqing
    Zhong Li
    Guo Yanli
    Shen Bing
    Huang Haiyun
    Wang Wenting
    Song Zhiyuan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C121 - C121
  • [22] Impact of left atrial appendage closure on left atrial hemodynamics: a prospective single center study
    Mertens, E.
    Bouziri, N.
    Guedeney, P.
    Duthoit, G.
    Redheuil, A.
    Ceccaldi, A.
    Chicheportiche, T.
    Isnard, R.
    Silvain, J.
    Montalescot, G.
    Hammoudi, N.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2661 - 2661
  • [23] Left atrial appendage closure in octogenarians: a single centre experience in Belgium
    de Molinari, Nicolas
    Descamps, Olivier
    Ceulemans, Auriane
    Mancini, Riccardo
    Badot, Damien
    Lepiece, Caroline
    de Meester, Antoine
    ACTA CARDIOLOGICA, 2024, 79 : 1 - 2
  • [24] Delayed pericardial effusion or tamponade following left atrial appendage closure: A single-center experience
    Fu, Guohua
    He, Bin
    Chu, Huimin
    Wang, Binhao
    Pan, Yuning
    Xie, Binhua
    Feng, Mingjun
    Du, Xianfeng
    Zhuo, Weidong
    Qi, Yingbo
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2023, 122 (08) : 707 - 713
  • [25] EFFICACY AND SAFETY OF LEFT ATRIAL APPENDAGE CLOSURE IN PATIENTS WITH ATRIAL FIBRILLATION FOR STROKE PREVENTION: SINGLE CENTER EXPERIENCE.
    Eichau, S.
    Perez-Sanchez, S.
    Dominguez-Mayoral, A.
    Gamero-Garcia, M. A.
    Abril-Jaramillo, J.
    De Torres, R.
    Perez-Noguera, R.
    Chavero-Moreno, E.
    Ruiz-Salmeron, R.
    CEREBROVASCULAR DISEASES, 2015, 39 : 224 - 224
  • [26] Left Atrial Appendage Closure Devices For Stroke Prevention
    Kapur, Sunil
    Mansour, Moussa
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2014, 3 (01) : 25 - 29
  • [27] Left atrial appendage closure with 2 different devices
    Ruiz-Nodar, Juan M.
    Ibanez Criado, Jose L.
    Climent Paya, Vicente
    REVISTA ESPANOLA DE CARDIOLOGIA, 2020, 73 (06): : 498 - 498
  • [28] Retrieval of embolised left atrial appendage closure devices
    Kany, Shinwan
    Bordignon, Stefano
    Piorkowski, Michael
    Chen, Shaojie
    Chun, K. R. Julian
    Tohoku, Shota
    Schmidt, Boris
    EUROINTERVENTION, 2021, 17 (02) : E178 - +
  • [29] Left Atrial Appendage Closure Outcomes in Patients With Cancer at a Single Tertiary Center
    Kumar, Sundeep
    Yoon, SungHan
    Milioglou, Ioannis
    Tashtish, Nour
    Farmakis, Ioannis
    Dallan, Luis Augusto Palma
    Mogalapalli, Akhil
    Arruda, Mauricio
    Filby, Steven J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 202 : 176 - 181
  • [30] Indications for and outcome with the left atrial appendage occluder - a single center experience
    Sieghartsleitner, R.
    Toth-Gayor, G.
    Zweiker, D.
    Manninger-Wuenscher, M.
    Odeneg, T.
    Mastnak, B.
    Ablasser, K.
    Stoschitzky, G.
    Maier, R.
    Luha, O.
    Brussee, H.
    Scherr, D.
    WIENER KLINISCHE WOCHENSCHRIFT, 2017, 129 : S97 - S97