Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist

被引:21
|
作者
Sutherland, John K. [1 ]
Nozaki, Taiki [1 ]
Kaneko, Yasuhito [1 ]
Yu, Hon J. [2 ,3 ]
Rafijah, Gregory [4 ]
Hitt, David [5 ]
Yoshioka, Hiroshi [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, UCI Med Ctr, Orange, CA 92686 USA
[2] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92686 USA
[3] John Tu & Thomas Yuen Ctr Funct Oncoimaging Irvin, Irvine, CA USA
[4] Univ Calif Irvine, Dept Orthopaed Surg, Irvine, CA 92686 USA
[5] Philips Med Syst, Cleveland, OH USA
来源
关键词
Musculoskeletal MRI; 3D MR imaging; MR arthrography; Wrist MRI; SPIN-ECHO; TRIANGULAR FIBROCARTILAGE; LIGAMENTS; PAIN; ARTHROSCOPY; KNEE;
D O I
10.1186/s12891-016-0890-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Methods: Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Results: Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). Conclusions: 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any obliquity to follow the components of ulnar side wrist structures including triangular fibrocartilage complex. Additionally, isotropic imaging provides thinner slice thickness with less partial volume averaging allowing for identification of subtle injuries.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comparison Between High-Resolution Isotropic Three-Dimensional and High-Resolution Conventional Two-Dimensional FSE MR Images of the Wrist at 3 Tesla: A Pilot Study
    Yamabe, Eiko
    Anavim, Arash
    Sakai, Toshinori
    Miyagi, Ryo
    Nakamura, Toshiyasu
    Hitt, Dave
    Yoshioka, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) : 603 - 608
  • [42] Inner ear volumetric measurements using high-resolution 3D T2-weighted fast spin-echo MR imaging: Initial experience in healthy subjects
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    MacDonald, CB
    Gira, J
    Caruthers, SD
    Jara, H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (10) : 1819 - 1822
  • [43] High-resolution 3D isotropic MR imaging of mouse flank tumours obtained in vivo with solenoid RF micro-coil
    Holmes, W. M.
    Maclellan, S.
    Condon, B.
    Dufes, C.
    Evans, T. R. J.
    Uchegbu, I. F.
    Schaetzlein, A. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (02): : 505 - 513
  • [44] Fast High-Resolution 3D Radar Imaging Based on 3D FISTA
    Ren, Jiaying
    Lu, Xinfei
    Guan, Jian
    Yin, Zhiping
    Ehen, Weidong
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 815 - 818
  • [45] Preliminary Study of 1.5-T MR Arthrography of the Shoulder With 3D Isotropic Intermediate-Weighted Turbo Spin Echo
    Rybak, Leon D.
    Vieira, Renata La Rocca
    Recht, Michael
    Shepard, Timothy
    Wiggins, Graham
    Babb, James
    Glaser, Christian
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : W107 - W113
  • [46] HIGH-RESOLUTION CT OF THE WRIST - INITIAL EXPERIENCE WITH SCAPHOID DISORDERS AND SURGICAL FUSIONS
    BUSH, CH
    GILLESPY, T
    DELL, PC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (04) : 757 - 760
  • [47] High-resolution, 3D T2-weighted Images with Isotropic Voxels for MRI-based Adaptive Brachytherapy
    Paulson, E. S.
    Erickson, B.
    Rownd, J.
    Ahunbay, E.
    Prost, R. W.
    Hohenwalter, M.
    Li, X. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S368 - S369
  • [48] High-Resolution 3D Radial bSSFP with IDEAL
    Moran, Catherine J.
    Brodsky, Ethan K.
    Bancroft, Leah Henze
    Reeder, Scott B.
    Yu, Huanzhou
    Kijowski, Richard
    Engel, Dorothee
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 95 - 104
  • [49] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738
  • [50] On the road to high-resolution 3D molecular imaging
    Delcorte, Arnaud
    APPLIED SURFACE SCIENCE, 2008, 255 (04) : 954 - 958