Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist

被引:21
|
作者
Sutherland, John K. [1 ]
Nozaki, Taiki [1 ]
Kaneko, Yasuhito [1 ]
Yu, Hon J. [2 ,3 ]
Rafijah, Gregory [4 ]
Hitt, David [5 ]
Yoshioka, Hiroshi [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, UCI Med Ctr, Orange, CA 92686 USA
[2] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92686 USA
[3] John Tu & Thomas Yuen Ctr Funct Oncoimaging Irvin, Irvine, CA USA
[4] Univ Calif Irvine, Dept Orthopaed Surg, Irvine, CA 92686 USA
[5] Philips Med Syst, Cleveland, OH USA
来源
关键词
Musculoskeletal MRI; 3D MR imaging; MR arthrography; Wrist MRI; SPIN-ECHO; TRIANGULAR FIBROCARTILAGE; LIGAMENTS; PAIN; ARTHROSCOPY; KNEE;
D O I
10.1186/s12891-016-0890-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Methods: Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Results: Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). Conclusions: 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any obliquity to follow the components of ulnar side wrist structures including triangular fibrocartilage complex. Additionally, isotropic imaging provides thinner slice thickness with less partial volume averaging allowing for identification of subtle injuries.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Non-invasive, high-resolution, 3D MR venography of the brain
    Reichenbach, JR
    Venkatesan, R
    Haacke, EM
    Kido, DK
    Lee, BC
    Kaiser, WA
    RADIOLOGY, 1997, 205 : 1138 - 1138
  • [22] High-resolution 3D MR imaging of aging ciliary body and lens
    Strenk, SA
    Jacob, J
    Strenk, LM
    Alvarez, T
    Semmlow, JL
    DeMarco, JK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4567 - 4567
  • [23] High-resolution 3D printing in seconds
    Darkes-Burkey, Cameron
    Shepherd, Robert F.
    NATURE, 2020, 588 (7839) : 594 - 595
  • [24] 3D High-Resolution Geophysical Surveys
    Sack, Peter
    Haugland, Tor
    SEA TECHNOLOGY, 2012, 53 (10) : 23 - +
  • [25] 3D mapping with high-resolution images
    Toutin, T
    Chénier, R
    Carbonneau, Y
    Alcaïde, N
    GEOINFORMATION FOR EUROPEAN-WIDE INTEGRATION, 2003, : 121 - 125
  • [26] High-resolution 3D survey of artworks
    Fontana, R
    Gambino, MC
    Mazzotta, C
    Greco, M
    Pampaloni, E
    Pezzati, L
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 719 - 726
  • [27] High-resolution 3D imaging of tissue
    Burgess, Sean A.
    Yuan, Baohong
    Radosevich, Andrew J.
    Bouchard, Mathew B.
    Hillman, Elizabeth M. C.
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 5 - 6
  • [28] High-Resolution 3D Printing for Electronics
    Park, Young-Geun
    Yun, Insik
    Chung, Won Gi
    Park, Wonjung
    Lee, Dong Ha
    Park, Jang-Ung
    ADVANCED SCIENCE, 2022, 9 (08)
  • [29] High-resolution 3D printing in seconds
    Cameron Darkes-Burkey
    Robert F. Shepherd
    Nature, 2020, 588 : 594 - 595
  • [30] High-resolution 3D mapping of loops
    Linda Koch
    Nature Reviews Genetics, 2015, 16 (2) : 68 - 68