Numerical simulation of noninvasive blood pressure measurement

被引:5
|
作者
Hayashi, Satoru
Hayase, Toshiyuki
Shirai, Atsushi
Maruyama, Masaru
机构
[1] Tohoku Univ, Izumi Ku, Sendai, Miyagi 9813202, Japan
[2] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai, Miyagi 9808577, Japan
[3] Tohoku Elect Power Co Inc, Aoba Ku, Sendai, Miyagi 9808550, Japan
关键词
bio-fluid mechanics; noninvasive blood pressure measurement; Korotkoff sounds; collapsible tube; numerical analysis;
D O I
10.1115/1.2241592
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper a simulation model based on the partially pressurized collapsible tube model for reproducing noninvasive blood pressure measurement is presented. The model consists of a collapsible tube, which models the pressurized part of the artery, rigid pipes connected to the collapsible tube, which model proximal and distal region far from the pressurized part, and the Windkessel model, which represents the capacitance and the resistance of the distal part of the circulation. The blood flow is simplified to a one-dimensional system. Collapse and expansion of the tube is represented by the change in the cross-sectional area of the tube considering the force balance acting on the tube membrane in the direction normal to the tube axis. They are solved using the Runge-Kutta method. This simple model can easily reproduce the oscillation of inner fluid and corresponding tube collapse typical for the Korotkoff sounds generated by the cuff pressure. The numerical result is compared with the experiment and shows good agreement.
引用
收藏
页码:680 / 687
页数:8
相关论文
共 50 条
  • [31] Policy Statement of the World Hypertension League on Noninvasive Blood Pressure Measurement Devices and Blood Pressure Measurement in the Clinical or Community Setting
    Campbell, Norm R. C.
    Berbari, Adel E.
    Cloutier, Lyne
    Gelfer, Mark
    Kenerson, John G.
    Khalsa, Tej K.
    Lackland, Daniel T.
    Lemogoum, Daniel
    Mangat, Birinder K.
    Mohan, Sailesh
    Myers, Martin G.
    Niebylski, Mark L.
    O'Brien, Eoin
    Stergiou, George S.
    Veiga, Eugenia Velludo
    Zhang, Xin-Hua
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (05): : 320 - 322
  • [32] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT FROM THE FINGER - FACTORS AFFECTING THE MEASUREMENT
    KURKI, TS
    SMITH, NT
    HEAD, N
    DECSILVER, H
    QUINN, A
    ANESTHESIOLOGY, 1986, 65 (3A) : A134 - A134
  • [33] Augmented blood pressure measurement through the noninvasive estimation of physiological arterial pressure variability
    Soueidan, Karen
    Chen, Silu
    Dajani, Hilmi R.
    Bolic, Miodrag
    Groza, Voicu
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (06) : 881 - 899
  • [34] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN NEONATES AND INFANTS WITH THE OSCILLOMETRIC METHOD
    PAPADOPOULOS, G
    ANAESTHESIST, 1994, 43 (07): : 441 - 446
  • [35] Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement
    Krejcar, Ondrej
    Janckulik, Dalibor
    Motalova, Leona
    Frischer, Robert
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 137 - +
  • [36] A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
    Miao, Yu
    Zhang, Zhiqiang
    Meng, Lifang
    Xie, Xiaoqin
    Pan, Haiwei
    SMART HEALTH, ICSH 2016, 2017, 10219 : 109 - 120
  • [37] Noninvasive blood pressure measurement in the upper and lower limbs of anaesthetized children
    Short, JA
    PAEDIATRIC ANAESTHESIA, 2000, 10 (06): : 591 - 593
  • [38] Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff:Implications for noninvasive blood pressure measurement
    Zhipeng Deng
    Fuyou Liang
    Acta Mechanica Sinica, 2016, 32 (05) : 959 - 969
  • [39] Noninvasive blood pressure measurement in mice using pulsed Doppler ultrasound
    Reddy, AK
    Taffet, GE
    Madala, S
    Michael, LH
    Entman, ML
    Hartley, CJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 379 - 385
  • [40] Validation of oscillometric noninvasive blood pressure measurement devices using simulators
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Vacher, Emilie
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2007, 12 (04) : 251 - 253