Numerical simulation of noninvasive blood pressure measurement

被引:5
|
作者
Hayashi, Satoru
Hayase, Toshiyuki
Shirai, Atsushi
Maruyama, Masaru
机构
[1] Tohoku Univ, Izumi Ku, Sendai, Miyagi 9813202, Japan
[2] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai, Miyagi 9808577, Japan
[3] Tohoku Elect Power Co Inc, Aoba Ku, Sendai, Miyagi 9808550, Japan
关键词
bio-fluid mechanics; noninvasive blood pressure measurement; Korotkoff sounds; collapsible tube; numerical analysis;
D O I
10.1115/1.2241592
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper a simulation model based on the partially pressurized collapsible tube model for reproducing noninvasive blood pressure measurement is presented. The model consists of a collapsible tube, which models the pressurized part of the artery, rigid pipes connected to the collapsible tube, which model proximal and distal region far from the pressurized part, and the Windkessel model, which represents the capacitance and the resistance of the distal part of the circulation. The blood flow is simplified to a one-dimensional system. Collapse and expansion of the tube is represented by the change in the cross-sectional area of the tube considering the force balance acting on the tube membrane in the direction normal to the tube axis. They are solved using the Runge-Kutta method. This simple model can easily reproduce the oscillation of inner fluid and corresponding tube collapse typical for the Korotkoff sounds generated by the cuff pressure. The numerical result is compared with the experiment and shows good agreement.
引用
收藏
页码:680 / 687
页数:8
相关论文
共 50 条
  • [21] Development of a Noninvasive Continuous Blood Pressure Measurement and Monitoring System
    Islam, Md. Manirul
    Rafi, Fida Hasan Md.
    Mitul, Abu Farzan
    Ahmad, Mohiuddin
    Rashid, M. A.
    bin Abd Malek, Mohd Fareq
    2012 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2012, : 1085 - 1090
  • [22] Noninvasive Cuffless Blood Pressure Measurement by Vascular Transit Time
    Shukla, Satya Narayan
    Kakwani, Karan
    Patra, Amit
    Lahkar, Bipin Kumar
    Gupta, Vivek Kumar
    Jayakrishna, Alwar
    Vashisht, Puneet
    Sreekanth, Induja
    2015 28TH INTERNATIONAL CONFERENCE ON VLSI DESIGN (VLSID), 2015, : 535 - 540
  • [23] A NOVEL CONTINUOUS AND NONINVASIVE MEASUREMENT FOR BLOOD PRESSURE BASED ON PHOTOPLETHYSMOGRAPHY
    Li, Xiru
    Li, Xiaofeng
    Xu, Jinlin
    Tan, Haibo
    Yuan, Munan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [24] Noninvasive measurement of systolic blood pressure in rats: A novel technique
    Gangwar, Anil
    Kumar, Pradeep
    Rawat, Anita
    Tiwari, Sunita
    INDIAN JOURNAL OF PHARMACOLOGY, 2014, 46 (03) : 351 - 352
  • [25] NONINVASIVE MEASUREMENT OF BLOOD-PRESSURE IN CONSCIOUS CYNOMOLGUS MONKEYS
    CHESTER, AE
    DORR, AE
    LUND, KR
    WOOD, LD
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1992, 19 (01): : 64 - 68
  • [26] Noninvasive Accelerometric Approach for Cuffless Continuous Blood Pressure Measurement
    Das, Mousumi
    Choudhary, Tilendra
    Sharma, L. N.
    Bhuyan, M. K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [27] The Noninvasive Blood Pressure Measurement Based on Facial Images Processing
    Zhou, Yimin
    Ni, Haiyang
    Zhang, Qi
    Wu, Qingtian
    IEEE SENSORS JOURNAL, 2019, 19 (22) : 10624 - 10634
  • [28] OPTIMIZING CUFF WIDTH FOR THE NONINVASIVE MEASUREMENT OF BLOOD-PRESSURE
    MARKS, LA
    GROCH, AJ
    CIRCULATION, 1994, 90 (04) : 616 - 616
  • [29] Noninvasive Simultaneous Measurement of Blood Pressure and Blood Flow Velocity for Hemodynamic Analysis
    Kato, Yuki
    Yoshimoto, Shunsuke
    Kuroda, Yoshihiro
    Imura, Masataka
    Yamashita, Shingo
    Ogura, Toshihiko
    Oshiro, Osamu
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2570 - 2573
  • [30] Noninvasive blood pressure measurement compared with intra-arterial blood pressure during vigorous motion
    Vikenes, K
    Omvik, P
    JOURNAL OF HYPERTENSION, 2003, 21 : S24 - S24