Numerical simulation of noninvasive blood pressure measurement

被引:5
|
作者
Hayashi, Satoru
Hayase, Toshiyuki
Shirai, Atsushi
Maruyama, Masaru
机构
[1] Tohoku Univ, Izumi Ku, Sendai, Miyagi 9813202, Japan
[2] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai, Miyagi 9808577, Japan
[3] Tohoku Elect Power Co Inc, Aoba Ku, Sendai, Miyagi 9808550, Japan
关键词
bio-fluid mechanics; noninvasive blood pressure measurement; Korotkoff sounds; collapsible tube; numerical analysis;
D O I
10.1115/1.2241592
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper a simulation model based on the partially pressurized collapsible tube model for reproducing noninvasive blood pressure measurement is presented. The model consists of a collapsible tube, which models the pressurized part of the artery, rigid pipes connected to the collapsible tube, which model proximal and distal region far from the pressurized part, and the Windkessel model, which represents the capacitance and the resistance of the distal part of the circulation. The blood flow is simplified to a one-dimensional system. Collapse and expansion of the tube is represented by the change in the cross-sectional area of the tube considering the force balance acting on the tube membrane in the direction normal to the tube axis. They are solved using the Runge-Kutta method. This simple model can easily reproduce the oscillation of inner fluid and corresponding tube collapse typical for the Korotkoff sounds generated by the cuff pressure. The numerical result is compared with the experiment and shows good agreement.
引用
收藏
页码:680 / 687
页数:8
相关论文
共 50 条
  • [1] Noninvasive Blood Pressure Measurement in Neonates
    Solevag, Anne Lee
    Saugstad, Ola Didrik
    JOURNAL OF PEDIATRICS, 2021, 235 : 57 - 57
  • [2] NONINVASIVE BLOOD-PRESSURE MEASUREMENT
    SANFORD, TJ
    JONES, BR
    SMITH, NT
    ANESTHESIOLOGY CLINICS OF NORTH AMERICA, 1988, 6 (04): : 721 - 741
  • [3] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [4] Automatic Noninvasive Measurement of Arterial Blood Pressure
    Nitzan, Meir
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2011, 14 (01) : 32 - 37
  • [5] A novel art of continuous noninvasive blood pressure measurement
    Jürgen Fortin
    Dorothea E. Rogge
    Christian Fellner
    Doris Flotzinger
    Julian Grond
    Katja Lerche
    Bernd Saugel
    Nature Communications, 12
  • [6] NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT IN PSYCHOPHYSIOLOGY
    GODAERT, G
    KRUITWAGEN, J
    JASPERS, J
    PSYCHOPHYSIOLOGY, 1985, 22 (05) : 591 - 592
  • [7] Validity and application of noninvasive measurement of blood pressure in hamsters
    Kato, Y
    Iwase, M
    Kanazawa, H
    Nishizawa, T
    Zhao, YL
    Takagi, K
    Nagata, K
    Noda, A
    Koike, Y
    Yokota, M
    EXPERIMENTAL ANIMALS, 2003, 52 (04) : 359 - 363
  • [9] Accuracy improvement of noninvasive finger blood pressure measurement
    Lackovic, I
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 281 - 284
  • [10] A novel art of continuous noninvasive blood pressure measurement
    Fortin, Juergen
    Rogge, Dorothea E.
    Fellner, Christian
    Flotzinger, Doris
    Grond, Julian
    Lerche, Katja
    Saugel, Bernd
    NATURE COMMUNICATIONS, 2021, 12 (01)