Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes

被引:0
|
作者
Baldini, E
Dall'Orto, VC
Danilowicz, C
Rezzano, I
Calvo, EJ
机构
[1] INQUIMAE, Dept Quim Inorgan Analit & Quim Fis, Fac Ciencias Exactas & Nat, AR-1428 Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Farm & Bioquim, AR-1113 Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
biosensor; peroxide; enzyme; HRP; biomimetic; porphyrin;
D O I
10.1002/1521-4109(200209)14:17<1157::AID-ELAN1157>3.0.CO;2-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors designed with crosslinked redox hydrogel and horseradish peroxidase have been evaluated in aqueous and nonaqueous media. Electrodes made of a single layer of active material were prepared with Os(bYP)(2)ClPyCH2 NHPoly(allylamine) polymer, (PAA-Os), attached to the enzyme by PEG-400 bifunctional reagent with the Os sites acting as electron wires. The electrodes proved to be stable in the presence of organic solvent considering the time evolution of the redox charge and the catalytic current. However, a reasonable decrease in the enzyme response is apparent while increasing solvent content in solution for detection of hydrogen and lauroyl peroxide. As an alternative biomimetic strategy, electrodes were modified with consecutive layers of PAA-Os and electropolymerized Fe-protoporphyrin IX. The electrochemical detection of peroxides was also possible with this system, proving that the poly[Fe-protoporphyrin IX]/Osmium complex system can mimic the peroxidase activity towards hydrogen and organic peroxides. The replacement of Fe-protoporphyrin by Ni-protoporphyrin IX and PAA-Os by PAA in different experiments demonstrates that the mechanism for peroxide reduction involves both Os and Fe-protoporphyrin IX sites. The enzymatic electrodes were applied to benzoyl peroxide quantitation in a pharmaceutical product. The method validation demonstrates that a simple and rapid FIA detection can be applied.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [41] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [42] CATALYTIC ELECTROREDUCTION OF MOLECULAR-OXYGEN USING PORPHYRIN MODIFIED ELECTRODES
    KOBAYASHI, N
    FUJIHIRA, M
    OSA, T
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (03) : C132 - C132
  • [43] Ruthenium/rhodium modified gold electrodes for the amperometric detection of hydrogen peroxide at low potentials
    Janasek, Dirk
    Vastarella, Walter
    Spohn, Uwe
    Teuscher, Nico
    Heilmann, Andreas
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (7-8) : 1267 - 1273
  • [44] Electrocatalytic oxidation and amperometric detection of ethanol on graphite electrodes modified with a coating composed of hexacyanometallates
    Shaidarova, LG
    Gedmina, AV
    Chelnokova, IA
    Budnikov, GK
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2004, 77 (12) : 1951 - 1957
  • [45] Electrocatalytic oxidation and amperometric detection of ethanol on graphite electrodes modified with a coating composed of hexacyanometallates
    L. G. Shaidarova
    A. V. Gedmina
    I. A. Chelnokova
    G. K. Budnikov
    Russian Journal of Applied Chemistry, 2004, 77 : 1951 - 1957
  • [47] Amperometric detection of ethanol with poly-(o-phenylenediamine)-modified enzyme electrodes
    Castanon, MJL
    Ordieres, AJM
    Blanco, PT
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (06): : 511 - 520
  • [48] Ruthenium/rhodium modified gold electrodes for the amperometric detection of hydrogen peroxide at low potentials
    Dirk Janasek
    Walter Vastarella
    Uwe Spohn
    Nico Teuscher
    Andreas Heilmann
    Analytical and Bioanalytical Chemistry, 2002, 374 : 1267 - 1273
  • [49] Voltammetric characterization and amperometric detection of β-carboline alkaloids at carbon nanotube-modified electrodes
    Agui, L.
    Pena-Farfal, C.
    Yanez-Sedeno, R.
    Pingarron, J. M.
    ELECTROANALYSIS, 2007, 19 (2-3) : 237 - 243
  • [50] Voltammetry and amperometric detection of tetracyclines at multi-wall carbon nanotube modified electrodes
    Vega, D.
    Aguei, L.
    Gonzalez-Cortes, A.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (03) : 951 - 958