Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes

被引:0
|
作者
Baldini, E
Dall'Orto, VC
Danilowicz, C
Rezzano, I
Calvo, EJ
机构
[1] INQUIMAE, Dept Quim Inorgan Analit & Quim Fis, Fac Ciencias Exactas & Nat, AR-1428 Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Farm & Bioquim, AR-1113 Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
biosensor; peroxide; enzyme; HRP; biomimetic; porphyrin;
D O I
10.1002/1521-4109(200209)14:17<1157::AID-ELAN1157>3.0.CO;2-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors designed with crosslinked redox hydrogel and horseradish peroxidase have been evaluated in aqueous and nonaqueous media. Electrodes made of a single layer of active material were prepared with Os(bYP)(2)ClPyCH2 NHPoly(allylamine) polymer, (PAA-Os), attached to the enzyme by PEG-400 bifunctional reagent with the Os sites acting as electron wires. The electrodes proved to be stable in the presence of organic solvent considering the time evolution of the redox charge and the catalytic current. However, a reasonable decrease in the enzyme response is apparent while increasing solvent content in solution for detection of hydrogen and lauroyl peroxide. As an alternative biomimetic strategy, electrodes were modified with consecutive layers of PAA-Os and electropolymerized Fe-protoporphyrin IX. The electrochemical detection of peroxides was also possible with this system, proving that the poly[Fe-protoporphyrin IX]/Osmium complex system can mimic the peroxidase activity towards hydrogen and organic peroxides. The replacement of Fe-protoporphyrin by Ni-protoporphyrin IX and PAA-Os by PAA in different experiments demonstrates that the mechanism for peroxide reduction involves both Os and Fe-protoporphyrin IX sites. The enzymatic electrodes were applied to benzoyl peroxide quantitation in a pharmaceutical product. The method validation demonstrates that a simple and rapid FIA detection can be applied.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [21] Tetralactam-modified gold electrodes for amperometric detection of acrylic acid
    Krajewska, A.
    Smet, M.
    Dehaen, W.
    Radecka, H.
    SUPRAMOLECULAR CHEMISTRY, 2009, 21 (06) : 520 - 531
  • [22] Amperometric detection of ethanol with poly-(ophenylenediamine) modified enzyme electrodes
    Lobo Castañón, M.J.
    Miranda Ordieres, A.J.
    Tuñón Blanco, P.
    Biosensors and Bioelectronics, 1997, 12 (06): : 511 - 520
  • [23] ZEOLITE PORPHYRIN MODIFIED ELECTRODES
    DEVISMES, B
    BEDIOUI, F
    DEVYNCK, J
    BIEDCHARRETON, C
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 187 (01): : 197 - 202
  • [24] Physicochemical peculiarities of iron porphyrin-containing electrodes in catalase- and peroxidase-type biomimetic sensors
    Sardarly, N. A.
    Nagiev, T. M.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2009, 83 (08) : 1400 - 1404
  • [25] Physicochemical peculiarities of iron porphyrin-containing electrodes in catalase- and peroxidase-type biomimetic sensors
    N. A. Sardarly
    T. M. Nagiev
    Russian Journal of Physical Chemistry A, 2009, 83 : 1400 - 1404
  • [26] Amperometric Ethanol Detection Using FIA and Screen-Printed Carbon Electrodes Modified with Metal Oxides
    Metelka, Radovan
    Jirkovska, Dana
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 82 - 85
  • [27] Analysis of polyphenols in white wine by CZE with amperometric detection using carbon nanotube-modified electrodes
    Moreno, Monica
    Sanchez Arribas, Alberto
    Bermejo, Esperanza
    Zapardiel, Antonio
    Chicharro, Manuel
    ELECTROPHORESIS, 2011, 32 (08) : 877 - 883
  • [28] Amperometric and voltammetric detection of hydrazine using glassy carbon electrodes modified with carbon nanotubes and catechol derivatives
    Salimi, Abdollah
    Miranzadeh, Layla
    Hallaj, Rahman
    TALANTA, 2008, 75 (01) : 147 - 156
  • [29] Determination of peroxides by capillary zone electrophoresis with amperometric detection
    Rüttinger, HH
    Radschuweit, A
    JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (01) : 127 - 134
  • [30] Amperometric DNA quantification based on the use of peroxidase-mercaptopropionic acid-modified gold electrodes
    Loaiza, Oscar A.
    Campuzano, Susana
    Guzman-Vazquez de Prada, Ana
    Pedrero, Maria
    Pingarron, Jose M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) : 250 - 257