Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes

被引:0
|
作者
Baldini, E
Dall'Orto, VC
Danilowicz, C
Rezzano, I
Calvo, EJ
机构
[1] INQUIMAE, Dept Quim Inorgan Analit & Quim Fis, Fac Ciencias Exactas & Nat, AR-1428 Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Farm & Bioquim, AR-1113 Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
biosensor; peroxide; enzyme; HRP; biomimetic; porphyrin;
D O I
10.1002/1521-4109(200209)14:17<1157::AID-ELAN1157>3.0.CO;2-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors designed with crosslinked redox hydrogel and horseradish peroxidase have been evaluated in aqueous and nonaqueous media. Electrodes made of a single layer of active material were prepared with Os(bYP)(2)ClPyCH2 NHPoly(allylamine) polymer, (PAA-Os), attached to the enzyme by PEG-400 bifunctional reagent with the Os sites acting as electron wires. The electrodes proved to be stable in the presence of organic solvent considering the time evolution of the redox charge and the catalytic current. However, a reasonable decrease in the enzyme response is apparent while increasing solvent content in solution for detection of hydrogen and lauroyl peroxide. As an alternative biomimetic strategy, electrodes were modified with consecutive layers of PAA-Os and electropolymerized Fe-protoporphyrin IX. The electrochemical detection of peroxides was also possible with this system, proving that the poly[Fe-protoporphyrin IX]/Osmium complex system can mimic the peroxidase activity towards hydrogen and organic peroxides. The replacement of Fe-protoporphyrin by Ni-protoporphyrin IX and PAA-Os by PAA in different experiments demonstrates that the mechanism for peroxide reduction involves both Os and Fe-protoporphyrin IX sites. The enzymatic electrodes were applied to benzoyl peroxide quantitation in a pharmaceutical product. The method validation demonstrates that a simple and rapid FIA detection can be applied.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [31] Formate dehydrogenase-modified carbon paste electrodes for amperometric detection of formate
    Munteanu, Florentina-Dainela
    Gligor, Delia
    Popescu, Ionel Catalin
    Gorton, Lo
    REVUE ROUMAINE DE CHIMIE, 2006, 51 (01) : 25 - 30
  • [32] Pulsed amperometric detection of histamine at glassy carbon electrodes modified with gold nanoparticles
    Carralero, V
    González-Cortés, A
    Yáñez-Sedeño, P
    Pingarrón, JM
    ELECTROANALYSIS, 2005, 17 (04) : 289 - 297
  • [33] Amperometric detection of hydrazine by cyclic voltammetry and flow injection analysis using ruthenium modified glassy carbon electrodes
    Pinter, Jill S.
    Brown, Kenneth L.
    DeYoung, Paul A.
    Peaslee, Graham F.
    TALANTA, 2007, 71 (03) : 1219 - 1225
  • [34] KINETICS OF PEROXIDASE REDUCTION AT MODIFIED ELECTRODES
    RAZUMAS, V
    GUDAVICIUS, A
    KULYS, J
    SOVIET ELECTROCHEMISTRY, 1987, 23 (01): : 121 - 126
  • [35] REACTIVITIES OF AMPEROMETRIC ORGANIC-PHASE PEROXIDASE-MODIFIED ELECTRODES IN THE PRESENCE AND ABSENCE OF THIOUREA AND ETHYLENETHIOUREA AS INHIBITORS
    ADEYOJU, O
    IWUOHA, EI
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 57 - 64
  • [36] Nanozymes 'artificial peroxidase' in reduction and detection of organic peroxides
    Komkova, Maria A.
    Zarochintsev, Alexander A.
    Karyakin, Arkady A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 904
  • [37] CHEMICAL MODIFIED ELECTRODES AS AMPEROMETRIC SENSORS IN ELECTROANALYSIS
    BUDNIKOV, H
    LABUDA, J
    USPEKHI KHIMII, 1992, 61 (08) : 1491 - 1514
  • [38] Phytase immobilization on modified electrodes for amperometric biosensing
    Moraes, Marli L.
    Oliveira, Osvaldo N.
    Rodrigues Filho, Ubirajara P.
    Ferreira, Marystela
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (01) : 210 - 215
  • [39] Chemically modified electrodes as amperometric sensors in electroanalysis
    Budnikov, G.Κ.
    Labuda, J.
    Russian Chemical Reviews, 1992, 61 (08) : 816 - 829
  • [40] Voltammetry and amperometric detection of tetracyclines at multi-wall carbon nanotube modified electrodes
    D. Vega
    L. Agüí
    A. González-Cortés
    P. Yáñez-Sedeño
    J. M. Pingarrón
    Analytical and Bioanalytical Chemistry, 2007, 389 : 951 - 958