Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes

被引:0
|
作者
Baldini, E
Dall'Orto, VC
Danilowicz, C
Rezzano, I
Calvo, EJ
机构
[1] INQUIMAE, Dept Quim Inorgan Analit & Quim Fis, Fac Ciencias Exactas & Nat, AR-1428 Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Farm & Bioquim, AR-1113 Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
biosensor; peroxide; enzyme; HRP; biomimetic; porphyrin;
D O I
10.1002/1521-4109(200209)14:17<1157::AID-ELAN1157>3.0.CO;2-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors designed with crosslinked redox hydrogel and horseradish peroxidase have been evaluated in aqueous and nonaqueous media. Electrodes made of a single layer of active material were prepared with Os(bYP)(2)ClPyCH2 NHPoly(allylamine) polymer, (PAA-Os), attached to the enzyme by PEG-400 bifunctional reagent with the Os sites acting as electron wires. The electrodes proved to be stable in the presence of organic solvent considering the time evolution of the redox charge and the catalytic current. However, a reasonable decrease in the enzyme response is apparent while increasing solvent content in solution for detection of hydrogen and lauroyl peroxide. As an alternative biomimetic strategy, electrodes were modified with consecutive layers of PAA-Os and electropolymerized Fe-protoporphyrin IX. The electrochemical detection of peroxides was also possible with this system, proving that the poly[Fe-protoporphyrin IX]/Osmium complex system can mimic the peroxidase activity towards hydrogen and organic peroxides. The replacement of Fe-protoporphyrin by Ni-protoporphyrin IX and PAA-Os by PAA in different experiments demonstrates that the mechanism for peroxide reduction involves both Os and Fe-protoporphyrin IX sites. The enzymatic electrodes were applied to benzoyl peroxide quantitation in a pharmaceutical product. The method validation demonstrates that a simple and rapid FIA detection can be applied.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [1] AMPEROMETRIC BIOSENSING OF ORGANIC PEROXIDES WITH PEROXIDASE-MODIFIED ELECTRODES
    WANG, J
    FREIHA, B
    NASER, N
    ROMERO, EG
    WOLLENBERGER, U
    OZSOZ, M
    EVANS, O
    ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) : 81 - 88
  • [2] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A.
    Emneus, J.
    Ruzgas, T.
    Gorton, L.
    Analytica Chimica Acta, 347 (1-2):
  • [3] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A
    Emneus, J
    Ruzgas, T
    Gorton, L
    MarkoVarga, G
    ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 51 - 62
  • [4] AMPEROMETRIC DETECTION OF PEROXIDES WITH POLY(ANILINOMETHYLFERROCENE)-MODIFIED ENZYME ELECTRODES
    MULCHANDANI, A
    WANG, CL
    WEETALL, HH
    ANALYTICAL CHEMISTRY, 1995, 67 (01) : 94 - 100
  • [5] ELECTROCATALYSIS AND AMPEROMETRIC DETECTION OF ORGANIC PEROXIDES AT MODIFIED CARBON-PASTE ELECTRODES
    WANG, J
    ANGNES, L
    LIANG, C
    EVANS, O
    TALANTA, 1991, 38 (10) : 1077 - 1081
  • [6] Amperometric detection of polyphenols using peroxidase-immobilized gold electrodes
    Imabayashi, S
    Kong, YT
    Watanabe, M
    CHEMISTRY LETTERS, 2000, (09) : 1020 - 1021
  • [7] Amperometric detection of nitrite and nitrate at tetraruthenated porphyrin-modified electrodes in a continuous-flow assembly
    da Rocha, JRC
    Angnes, L
    Bertotti, M
    Araki, K
    Toma, HE
    ANALYTICA CHIMICA ACTA, 2002, 452 (01) : 23 - 28
  • [8] BULK MODIFIED ENZYME ELECTRODES FOR REAGENTLESS DETECTION OF PEROXIDES
    WOLLENBERGER, U
    WANG, J
    OZSOZ, M
    GONZALEZROMERO, E
    SCHELLER, F
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02): : 287 - 296
  • [9] Amperometric determination of peroxides by glassy carbon electrodes modified with copper-phenanthroline complexes
    Toniolo, R
    Comisso, N
    Bontempelli, G
    Schiavon, G
    ELECTROANALYSIS, 1996, 8 (02) : 151 - 157
  • [10] Amperometric biosensor for the detection of hydrogen peroxide using catalase modified electrodes in polyacrylamide
    Varma, S
    Mattiasson, B
    JOURNAL OF BIOTECHNOLOGY, 2005, 119 (02) : 172 - 180