The performances of piezoelectric transformer for fluorescent T5 lamp

被引:0
|
作者
Lee, JS [1 ]
Lim, KJ
Lee, YH
Hong, JK
Kim, HH
Jeong, SH
机构
[1] Chungbuk Natl Univ, Dept Elect Engn, Cheongju, South Korea
[2] Doowon Coll, Dept Elect Engn, Ansung, South Korea
关键词
piezoelectric transformer; FEM; piezoelectric ballast;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The properties of circular type piezoelectric transformer for fluorescent T5 lamp are investigated as a function of area ratio of input part to output part. From the simulation result using FEM, as the area ratio increases, the voltage step-up ratio increases linearly. The voltage step-up ratio of output to input is about 1.6 when the area ratio is about 2. The new ballast using piezoelectric transformer is the type of series resonant half bridge inverter. As the results of performance test, when the input voltage is 220 V-rms, the step-up ratio is about 1.6 for fighting the lamp. Also, lamp current and output power are 150 mA and about 26 W in steady state, respectively. The efficiency is about 93 %. It is concluded that the PT fabricated in this study is available to the ballast for T5 lamp.
引用
收藏
页码:2503 / +
页数:8
相关论文
共 50 条
  • [31] T5 Consulting
    Tollast, Anthony
    EDUCATION FOR PRIMARY CARE, 2007, 18 (03) : 389 - 391
  • [32] Office lighting retrofit using T5 fluorescent lamps and electronic ballasts
    Wu, Martin K.T.
    Lam, K.K.
    HKIE Transactions Hong Kong Institution of Engineers, 2003, 10 (01): : 55 - 60
  • [33] VOLTAGE-FREQUENCY CONTROL DIMMING METHOD FOR T5 FLUORESCENT LAMPS
    Seidel, A. R.
    Bisogno, F. E.
    Alonso, J. M.
    Polonski, M.
    Schulz, V. H.
    2013 BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP), 2013, : 1189 - 1194
  • [34] Electronic Ballast with Digital Dimming Control for Multiple T5 Fluorescent Lamps
    Chen, Liang-Rui
    Wu, Shing-Lih
    Chu, Neng-Yi
    Hsiao, Yu-Chih
    Chen, Tsair-Rong
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (05): : 809 - 815
  • [35] Assessment of quality and reliability of measurements with XBT Sippican T5 and T5/20
    Cheng, Lijing (chenglij@mail.iap.ac.cn), 1935, American Meteorological Society (35):
  • [36] Assessment of Quality and Reliability of Measurements with XBT Sippican T5 and T5/20
    Reseghetti, Franco
    Cheng, Lijing
    Borghini, Mireno
    Yashayaev, Igor M.
    Raiteri, Giancarlo
    Zhu, Jiang
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2018, 35 (10) : 1935 - 1960
  • [37] T5 - BRUTE FORCE
    HALFHILL, TR
    BYTE, 1994, 19 (11): : 123 - &
  • [38] 漫话T5灯具
    谷青
    光源与照明, 2000, (02) : 41 - 45
  • [40] 半T5空间
    姜文玲
    丁杰
    陈洁
    天津职业大学学报, 2001, (02) : 30 - 32