The performances of piezoelectric transformer for fluorescent T5 lamp

被引:0
|
作者
Lee, JS [1 ]
Lim, KJ
Lee, YH
Hong, JK
Kim, HH
Jeong, SH
机构
[1] Chungbuk Natl Univ, Dept Elect Engn, Cheongju, South Korea
[2] Doowon Coll, Dept Elect Engn, Ansung, South Korea
关键词
piezoelectric transformer; FEM; piezoelectric ballast;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The properties of circular type piezoelectric transformer for fluorescent T5 lamp are investigated as a function of area ratio of input part to output part. From the simulation result using FEM, as the area ratio increases, the voltage step-up ratio increases linearly. The voltage step-up ratio of output to input is about 1.6 when the area ratio is about 2. The new ballast using piezoelectric transformer is the type of series resonant half bridge inverter. As the results of performance test, when the input voltage is 220 V-rms, the step-up ratio is about 1.6 for fighting the lamp. Also, lamp current and output power are 150 mA and about 26 W in steady state, respectively. The efficiency is about 93 %. It is concluded that the PT fabricated in this study is available to the ballast for T5 lamp.
引用
收藏
页码:2503 / +
页数:8
相关论文
共 50 条
  • [21] Electrical characteristics of high power piezoelectric transformer for 28 W fluorescent lamp
    Yoo, J
    Yoon, K
    Hwang, SM
    Suh, S
    Kim, J
    Yoo, C
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 90 (1-2) : 132 - 137
  • [22] Inductor-less piezoelectric transformer electronic ballast for linear fluorescent lamp
    Lin, RL
    Lee, FC
    Baker, EM
    Chen, DY
    APEC 2001: SIXTEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2001, : 664 - 669
  • [23] Arabic News Summarization based on T5 Transformer Approach
    Ismail, Qusai
    Alissa, Kefah
    Duwairi, Rehab M.
    2023 14th International Conference on Information and Communication Systems, ICICS 2023, 2023,
  • [24] Energy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system
    Chiradeja, P.
    Ngaopitakkul, A.
    Jettanasen, C.
    ENERGY AND BUILDINGS, 2015, 97 : 107 - 117
  • [25] The characteristics of new piezoelectric ballast for fluorescent T8 lamp
    Lee, JS
    Lee, YH
    Chai, HI
    Yoon, MS
    Lim, KJ
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 947 - 951
  • [27] Fluorescent Lamp Ballast based on a Class-E Resonant Inverter Using a Piezoelectric Transformer
    Ribas, J.
    Martin, J. A.
    Garcia, J.
    Cardesin, J.
    Calleja, A. J.
    Rico-Secades, M.
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 252 - 256
  • [28] Energy Saving in Lighting From T5 Lamp Retrofits - A Case Study
    ul Haq, Mohammad Asif
    Hassan, Mohammad Yusri
    Abdullah, Hayati
    Rahman, Hasimah Abdul
    Abdullah, Md. Pauzi
    Hussin, Faridah
    Bandi, Masilah
    2013 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2013), 2013, : 187 - 190
  • [29] Harvesting daylight with LED or T5 fluorescent lamps? The role of dimming
    Doulos, L. T.
    Tsangrassoulis, A.
    Kontaxis, P. A.
    Kontadakis, A.
    Topalis, F. V.
    ENERGY AND BUILDINGS, 2017, 140 : 336 - 347
  • [30] Influence of Cold Starting on the Life of T5 Fluorescent Tubes and CFLs
    Chondrakis, Nikolaos G.
    Topalis, Frangiskos V.
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 3354 - +