Chemiluminescence microflow injection analysis system on a chip for the determination of nitrite in food

被引:88
|
作者
He, Deyong [1 ]
Zhang, Zhujun [1 ]
Huang, Ying [1 ]
Hu, Yufei [1 ]
机构
[1] SW Normal Univ, Inst Analyt Sci, Key Lab Analyt Chem Chongqing, Chongqing 400715, Peoples R China
关键词
microflow injection analysis; chemiluminescence; nitrite; chip;
D O I
10.1016/j.foodchem.2006.02.024
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new microflow injection analysis (mu FIA) system on a chip for the determination of nitrite is described. The chip is produced by using two transparent poly(methylmethacrylate) (PMMA) slices measured 50 x 40 x 5 mm, and the microchannels etched by CO2 laser are 200 mu m wide and 100 mu m deep with the volume of reaction area about 1.8 mu L. Nitrite is sensed by the chemiluminescence (CL) reaction of luminol with ferricyanide that is the product of the reaction of ferrocyanide with nitrite in acidic medium. The syringe pump with an accurate timer controls all reagents, including the sample. The linear range of the nitrite concentration is 8-100 mu g L-1 and the detection limit is 4 mu g L-1 (S/N = 3). The proposed method has good reproducibility with the relative standard deviation 4.1% for 50 mu g L-1 of nitrite (n = 9) and is very sensitive and simple. It has been successfully applied to. the determination of nitrite in food. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [1] Chemiluminescence microflow injection analysis system on a chip for the determination of hydrogen peroxide in rainwater
    Huang, Y
    Zhang, ZJ
    He, DY
    Hu, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 958 - 960
  • [2] Chemiluminescence microflow injection analysis system on a chip for the determination of uric acid without enzyme
    He, DY
    Zhang, ZJ
    Huang, Y
    Hu, YF
    Zhou, HJ
    Chen, DL
    LUMINESCENCE, 2005, 20 (4-5) : 271 - 275
  • [3] Chemiluminescence microllow injection analysis system on a chip for the determination of sulfite in food
    He, DY
    Zhang, ZJ
    Huang, Y
    ANALYTICAL LETTERS, 2005, 38 (04) : 563 - 571
  • [4] A chemiluminescence flow injection system for nitrite ion determination
    Amini, M. K.
    Pourhossein, M.
    Talebi, M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2005, 2 (04) : 305 - 314
  • [5] A chemiluminescence flow injection system for nitrite ion determination
    M. K. Amini
    M. Pourhossein
    M. Talebi
    Journal of the Iranian Chemical Society, 2005, 2 : 305 - 314
  • [6] Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters
    del Mar Baeza, Maria
    Ibanez-Garcia, Nuria
    Baucells, Joan
    Bartroli, Jordi
    Alonso, Julian
    ANALYST, 2006, 131 (10) : 1109 - 1115
  • [7] Determination of nitrite in water samples by sequential injection analysis with chemiluminescence detection on chip flow cell
    Wang, Y
    Fan, SH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (02) : 184 - 187
  • [8] Microflow injection chemiluminescence system with spiral microchannel for the determination of cisplatin in human serum
    Wang, Xiuzhong
    Yin, Xuefeng
    Cheng, Heyong
    ANALYTICA CHIMICA ACTA, 2010, 678 (02) : 135 - 139
  • [9] Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination
    Greenway, GM
    Nelstrop, LJ
    Port, SN
    ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) : 43 - 50
  • [10] Determination of nitrite by electrokinetically sequential injection analysis system
    Zhao, YQ
    He, YZ
    Gan, WE
    Yang, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (04) : 440 - 442