A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer

被引:32
|
作者
Gasic, Daniel [1 ]
Ohlhues, Lars [1 ]
Brodin, N. Patrik [2 ]
Fog, Lotte S. [1 ]
Pommer, Tobias [1 ,3 ]
Bangsgaard, Jens P. [1 ]
Rosenschold, Per Munck A. F. [1 ,3 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Sect Radiotherapy, Copenhagen, Denmark
[2] Albert Einstein Coll Med, Inst Oncophys, Bronx, NY 10461 USA
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
关键词
STEREOTACTIC BODY RADIOTHERAPY; FREE BEAMS; PHOTON BEAMS; IMRT; SBRT; FEASIBILITY; VMAT; PATIENT;
D O I
10.3109/0284186X.2014.925578
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. Methods. A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD-and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. Results. For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. Conclusion. It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [41] Dosimetric advantages of dual arc increments for head and neck volumetric-modulated arc therapy in the Monaco treatment planning system
    Choi, Jin Hwa
    Ryu, Hyejo
    Oh, Do Hoon
    Yoo, Lee
    Chun, Minsoo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):
  • [42] DENTITION RECEIVING >50GY IN THE TREATMENT OF HEAD AND NECK CANCER WITH VOLUMETRIC MODULATED ARC THERAPY
    Lee, Nathan
    Berthelet, Eric
    RADIOTHERAPY AND ONCOLOGY, 2021, 163 : S43 - S44
  • [43] Helical tomotherapy and intensity modulated proton therapy in the treatment of early stage prostate cancer: A treatment planning comparison
    Schwarz, Marco
    Pierelli, Alessio
    Fiorino, Claudio
    Fellin, Francesco
    Cattaneo, Giovanni Mauro
    Cozzarini, Cesare
    Di Muzio, Nadia
    Calandrino, Riccardo
    Widesott, Lamberto
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (01) : 74 - 80
  • [44] Treatment planning and dosimetric comparison study on two different volumetric modulated arc therapy delivery techniques
    Kumar, S. A. Syam
    Holla, Raghavendra
    Sukumar, Prabakar
    Padmanaban, Sriram
    Vivekanandan, Nagarajan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (02) : 87 - 94
  • [45] Treatment planning comparison of volumetric modulated arc therapy with the trilogy and the Halcyon for bilateral breast cancer
    Tao Sun
    Xiutong Lin
    Guifang Zhang
    Qingtao Qiu
    Chengqiang Li
    Yong Yin
    Radiation Oncology, 16
  • [46] Treatment planning comparison of volumetric modulated arc therapy with the trilogy and the Halcyon for bilateral breast cancer
    Sun, Tao
    Lin, Xiutong
    Zhang, Guifang
    Qiu, Qingtao
    Li, Chengqiang
    Yin, Yong
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [47] Single-fraction flattening filter-free volumetric modulated arc therapy for lung cancer: Dosimetric results and comparison with flattened beams technique
    Barbiero, Sara
    Rink, Alexandra
    Matteucci, Fabrizio
    Fedele, David
    Paiar, Fabiola
    Pasqualetti, Francesco
    Avanzo, Michele
    MEDICAL DOSIMETRY, 2016, 41 (04) : 334 - 338
  • [48] Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study
    Holt, Andrea
    Van Gestel, Dirk
    Arends, Mark P.
    Korevaar, Erik W.
    Schuring, Danny
    Kunze-Busch, Martina C.
    Louwe, Rob J. W.
    van Vliet-Vroegindeweij, Corine
    RADIATION ONCOLOGY, 2013, 8
  • [49] Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study
    Andrea Holt
    Dirk Van Gestel
    Mark P Arends
    Erik W Korevaar
    Danny Schuring
    Martina C Kunze-Busch
    Rob JW Louwe
    Corine van Vliet-Vroegindeweij
    Radiation Oncology, 8
  • [50] Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
    Cakir, A.
    Akgun, Z.
    Saglam, E. Kaytan
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (02): : 253 - 263